Catalogue / MV metal-clad switchboards (11–33 kV)
Indoor MV switchgear panel with VCB, Flex seriesSample
by Kavachtek Switchboards (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Kavachtek Switchboards (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
The Flex range of indoor MV switchgear panel with VCB by Kavachtek covers 4 rating options (11 kV 2500 A to 33 kV 2000 A). Highlights: type test reports from recognised labs, IEC 61850 communication for substation automation and test facility for cable tests without isolating. Typically used for steel and cement plants, grid substations 33/11 kV and renewable plant evacuation boards. Designed and tested to IEC 62271-200, IEC 62271-100 and IS 3427. Lead time 12-16 weeks; delivers to South India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Kavachtek
- Model
- KAV-B86 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 5 nos
- Lead time
- 12-16 weeks
- Warranty
- 24 months from supply
- Standards
- IEC 62271-200, IEC 62271-100, IS 3427
- Delivers to
- South India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Drum / reel with end caps
- Delivery terms
- FOR nearest railhead
- Returns
- Replacement of items damaged in transit within 7 days
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Rating11 kV 2500 AKAV-B86-01 | Rating: 11 kV 2500 A | 5 nos · 12-16 weeks | for verified buyers |
| Rating22 kV 1250 AKAV-B86-02 | Rating: 22 kV 1250 A | 5 nos · 12-16 weeks | for verified buyers |
| Rating33 kV 1250 AKAV-B86-03 | Rating: 33 kV 1250 A | 5 nos · 12-16 weeks | for verified buyers |
| Rating33 kV 2000 AKAV-B86-04 | Rating: 33 kV 2000 A | 5 nos · 12-16 weeks | for verified buyers |
Specifications
| Rating | 11 kV 2500 A to 33 kV 2000 A (see variants) |
|---|---|
| Insulation | SF6 gas-insulated |
| Short-circuit rating | 31.5 kA/3 s |
| Panel function | Bus coupler |
| Busbar | Single busbar |
| Internal arc rating | IAC AFLR 31.5 kA 1 smade to order: IAC AFLR 40 kA 1 s |
| Loss of service continuity | LSC2Amade to order: LSC2B |
| Partition class | PM metallic partition |
| Auxiliary supply | 110 V DCmade to order: 220 V DC |
| Protection relays | Directional O/C |
| Communication | IEC 60870-5-103made to order: IEC 61850 / Modbus RTU |
| Bus VT | Withdrawable |
| Degree of protection | IP54made to order: IP4X |