Catalogue / Transformer overhaul & oil filtration
DGA based diagnostics and reclamation, Plus seriesSample
by Kaverispark Logistics (Sample) · verified by BARREL
Price on quote
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Kaverispark Logistics (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
DGA based diagnostics and reclamation from Kaverispark, Plus series: 5 transformer rating options between 5 MVA and 100 MVA. Key features: hot oil circulation under vacuum, nitrogen or dry air purge on opening and core insulation resistance checks. Suited to solar and wind pooling substations, industrial distribution transformers and captive power plants. Delivered in line with IS 335 (Mineral Insulating Oil), IS 1866 (Oil Maintenance) and IEC 60422. Mobilisation Planned shutdown required; serves North India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Kaverispark
- Model
- KAV-C06 series
- Listing type
- Service
- Unit
- nos
- Minimum order
- 1 nos
- Lead time
- Planned shutdown required
- Warranty
- Workmanship 12 months
- Standards
- IS 335 (Mineral Insulating Oil), IS 1866 (Oil Maintenance), IEC 60422
- Delivers to
- North India
- GST rate
- 18 %
- Country of origin
- India
- Delivery terms
- Site mobilisation as per work order
- Returns
- Re-work of defective scope at no cost
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Transformer rating5 MVAKAV-C06-01 | Transformer rating: 5 MVA | 1 nos · Planned shutdown required | on quote |
| Transformer rating10 MVAKAV-C06-02 | Transformer rating: 10 MVA | 1 nos · Planned shutdown required | on quote |
| Transformer rating20 MVAKAV-C06-03 | Transformer rating: 20 MVA | 1 nos · Planned shutdown required | on quote |
| Transformer rating50 MVAKAV-C06-04 | Transformer rating: 50 MVA | 1 nos · Planned shutdown required | on quote |
| Transformer rating100 MVAKAV-C06-05 | Transformer rating: 100 MVA | 1 nos · Planned shutdown required | on quote |
Specifications
| Transformer rating | 5 MVA to 100 MVA (see variants) |
|---|---|
| Service | Internal inspection and overhaul |
| Filtration machine | Mobile 12000 L/hr |
| Oil BDV target | Above 60 kVmade to order: Above 70 kV |
| Moisture target | Below 5 ppm |
| Testing | Full routine tests after overhaul |
| Spares | Gaskets and silica gel |
| Downtime | 3-4 weeksmade to order: 2-3 days / 5-7 days |
| Site work | Hot oil circulation at site |
| Crew | Specialised overhaul team |
| Certificate | Oil test report from NABL labmade to order: Overhaul report with test data |