Catalogue / Transformer overhaul & oil filtration

No photo yet

DGA based diagnostics and reclamation, Plus seriesSample

by Kaverispark Logistics (Sample) · verified by BARREL

Price on quote

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Kaverispark Logistics (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

DGA based diagnostics and reclamation from Kaverispark, Plus series: 5 transformer rating options between 5 MVA and 100 MVA. Key features: hot oil circulation under vacuum, nitrogen or dry air purge on opening and core insulation resistance checks. Suited to solar and wind pooling substations, industrial distribution transformers and captive power plants. Delivered in line with IS 335 (Mineral Insulating Oil), IS 1866 (Oil Maintenance) and IEC 60422. Mobilisation Planned shutdown required; serves North India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Kaverispark
Model
KAV-C06 series
Listing type
Service
Unit
nos
Minimum order
1 nos
Lead time
Planned shutdown required
Warranty
Workmanship 12 months
Standards
IS 335 (Mineral Insulating Oil), IS 1866 (Oil Maintenance), IEC 60422
Delivers to
North India
GST rate
18 %
Country of origin
India
Delivery terms
Site mobilisation as per work order
Returns
Re-work of defective scope at no cost
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Transformer rating5 MVAKAV-C06-01Transformer rating: 5 MVA1 nos · Planned shutdown requiredon quote
Transformer rating10 MVAKAV-C06-02Transformer rating: 10 MVA1 nos · Planned shutdown requiredon quote
Transformer rating20 MVAKAV-C06-03Transformer rating: 20 MVA1 nos · Planned shutdown requiredon quote
Transformer rating50 MVAKAV-C06-04Transformer rating: 50 MVA1 nos · Planned shutdown requiredon quote
Transformer rating100 MVAKAV-C06-05Transformer rating: 100 MVA1 nos · Planned shutdown requiredon quote

Specifications

Transformer rating5 MVA to 100 MVA (see variants)
ServiceInternal inspection and overhaul
Filtration machineMobile 12000 L/hr
Oil BDV targetAbove 60 kVmade to order: Above 70 kV
Moisture targetBelow 5 ppm
TestingFull routine tests after overhaul
SparesGaskets and silica gel
Downtime3-4 weeksmade to order: 2-3 days / 5-7 days
Site workHot oil circulation at site
CrewSpecialised overhaul team
CertificateOil test report from NABL labmade to order: Overhaul report with test data

BARREL: Bharat Atom Renewable Resources Energy Limited