Catalogue / Electrical safety audits
Statutory electrical compliance audit, Volt 9 seriesSample
by Kaverispark Logistics (Sample) · verified by BARREL
Price on quote
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Kaverispark Logistics (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Kaverispark Volt 9 statutory electrical compliance audit, offered in 3 installed load options from 1 MVA to 10 MVA. Key features: fire exit and detection checks, training recommendations for staff and compliance matrix against CEA safety rules. Suited to hospitals and commercial buildings, manufacturing plants and data centres. Delivered in line with Indian Electricity Act 2003, CEA (Measures relating to Safety) Regulations and IS 5216. Mobilisation Audit in 1-2 weeks; serves North India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Kaverispark
- Model
- KAV-752 series
- Listing type
- Service
- Unit
- site
- Minimum order
- 1 site
- Lead time
- Audit in 1-2 weeks
- Warranty
- Clarifications on report at no cost for 6 months
- Standards
- Indian Electricity Act 2003, CEA (Measures relating to Safety) Regulations, IS 5216
- Delivers to
- North India
- GST rate
- 18 %
- Country of origin
- India (imported sub-assemblies)
- Delivery terms
- Site mobilisation as per work order
- Returns
- Re-work of defective scope at no cost
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Installed load1 MVAKAV-752-01 | Installed load: 1 MVA | 1 site · Audit in 1-2 weeks | on quote |
| Installed load5 MVAKAV-752-02 | Installed load: 5 MVA | 1 site · Audit in 1-2 weeks | on quote |
| Installed load10 MVAKAV-752-03 | Installed load: 10 MVA | 1 site · Audit in 1-2 weeks | on quote |
Specifications
| Installed load | 1 MVA to 10 MVA (see variants) |
|---|---|
| Scope | Visual and documentation auditmade to order: Audit with measurements / Audit with arc-flash study |
| Auditor | Chartered engineer |
| Measurements | Thermography and power qualitymade to order: Earth resistance, insulation |
| Report | Action plan with timeline |
| Statutory records | Permit-to-work audit |
| Sampling | 100% of HV equipmentmade to order: Representative LV panels |
| Follow-up | Close-out verification |
| Turnaround | 3-4 weeks |
| Presentation | Report onlymade to order: Findings to management |
| Accreditation | Government recognised agencymade to order: ISO/IEC 17020 body |