Catalogue / Substation & line O&M
Switchyard preventive maintenance, Eco seriesSample
by Kaverispark Logistics (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Kaverispark Logistics (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
The Eco service of switchyard preventive maintenance by Kaverispark covers 6 voltage level options (11 kV to 400 kV). Highlights: fault analysis within 24 hours, insulator and joint inspection and permit-to-work and lockout-tagout. Used by railway and metro sub-stations, state utility outsourcing and renewable pooling substations. Delivered in line with CEA (Measures relating to Safety) Regulations, CEA (Grid Standards) Regulations and IS 10028 (Transformer Installation). Mobilisation Baseline condition audit first; serves North India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Kaverispark
- Model
- KAV-8E1 series
- Listing type
- Service
- Unit
- month
- Minimum order
- 1 month
- Lead time
- Baseline condition audit first
- Warranty
- As per contract
- Standards
- CEA (Measures relating to Safety) Regulations, CEA (Grid Standards) Regulations, IS 10028 (Transformer Installation)
- Delivers to
- North India
- GST rate
- 18 %
- Country of origin
- India
- Delivery terms
- Site mobilisation as per work order
- Returns
- Re-work of defective scope at no cost
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Voltage level11 kVKAV-8E1-01 | Voltage level: 11 kV | 1 month · Baseline condition audit first | for verified buyers |
| Voltage level33 kVKAV-8E1-02 | Voltage level: 33 kV | 1 month · Baseline condition audit first | for verified buyers |
| Voltage level66 kVKAV-8E1-03 | Voltage level: 66 kV | 1 month · Baseline condition audit first | for verified buyers |
| Voltage level132 kVKAV-8E1-04 | Voltage level: 132 kV | 1 month · Baseline condition audit first | for verified buyers |
| Voltage level220 kVKAV-8E1-05 | Voltage level: 220 kV | 1 month · Baseline condition audit first | for verified buyers |
| Voltage level400 kVKAV-8E1-06 | Voltage level: 400 kV | 1 month · Baseline condition audit first | for verified buyers |
Specifications
| Voltage level | 11 kV to 400 kV (see variants) |
|---|---|
| Scope | Maintenance only |
| Shift pattern | General shift plus on-callmade to order: 3 shifts, 24x7 |
| Manpower | Engineer plus 6 operators |
| Line patrolling | Monthly foot patrol |
| Testing | Thermography twice a yearmade to order: Annual relay and CT/PT test |
| Statutory records | Log books, permits, shutdown register |
| Spares | Consumables included |
| Response time | 2 hours for tripmade to order: 4 hours |
| Reporting | Monthly fault and maintenance reportmade to order: Real-time dashboards |
| Term | 3 yearsmade to order: 1 year |