Catalogue / Distribution transformer monitoring units (DTMU)
Transformer load and oil temperature monitor, Edge 3 seriesSample
by Konarkanant Meters (Sample) · verified by BARREL
Price on quote
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Konarkanant Meters (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Transformer load and oil temperature monitor from Konarkanant, Edge 3 series: 4 DT rating covered options between 100-200 kVA and 1250-2000 kVA. Highlights: oil temperature and tank vibration optional sensors, interface to discom SCADA/AMI platform and remote configuration of thresholds. Used by discom energy audit, theft detection at feeder/DT level and RDSS distribution loss reduction. Designed and tested to IS 16444, IS 15959 and IEC 62053-22. Lead time 3-4 weeks; delivers to South India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Konarkanant
- Model
- KON-2A3 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 5 nos
- Lead time
- 3-4 weeks
- Warranty
- 24 months from supply
- Standards
- IS 16444, IS 15959, IEC 62053-22
- Delivers to
- South India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Corrugated box on pallet
- Delivery terms
- Door delivery in metro cities
- Returns
- No returns on made-to-order items
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| DT rating covered100-200 kVAKON-2A3-01 | DT rating covered: 100-200 kVA | 5 nos · 3-4 weeks | on quote |
| DT rating covered250-400 kVAKON-2A3-02 | DT rating covered: 250-400 kVA | 5 nos · 3-4 weeks | on quote |
| DT rating covered500-1000 kVAKON-2A3-03 | DT rating covered: 500-1000 kVA | 5 nos · 6-8 weeks | on quote |
| DT rating covered1250-2000 kVAKON-2A3-04 | DT rating covered: 1250-2000 kVA | 5 nos · 6-8 weeks | on quote |
Specifications
| DT rating covered | 100-200 kVA to 1250-2000 kVA (see variants) |
|---|---|
| Measurement | V, I, kW, kVA, PF, THD |
| Accuracy class | 1.0 |
| CT input | Split-core CT 100/5 Amade to order: Split-core CT 600/5 A / CT 1000/1 A |
| Communication | GPRS/4G |
| Oil temperature sensor | Not included |
| Alarms | Overload, unbalance, phase failure, low voltage |
| Protocol | MQTT |
| Data interval | 15 min |
| Power supply | Aux 230 V |
| Enclosure | IP65 polycarbonate |
| Load survey | 60 days internal |