Catalogue / Mobile substations
Containerised mobile substation, Elite 4 seriesSample
by Konark Transformer Works (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Konark Transformer Works (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
Containerised mobile substation from Konark, Elite 4 series: 4 transformer rating options between 10 MVA and 50 MVA. Highlights: bay-extension and maintenance outage cover, compact oil spill containment and suitable for road transport within weight limits. Used by event power supply, maintenance outage support and mining sites. Designed and tested to IEC 62271-202, IS 2026 and IEC 60076. Lead time 30-40 weeks; delivers to East & North-East India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Konark
- Model
- KON-8E1 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 2 nos
- Lead time
- 30-40 weeks
- Warranty
- 24 months
- Standards
- IEC 62271-202, IS 2026, IEC 60076
- Delivers to
- East & North-East India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Wooden crate, seaworthy
- Delivery terms
- FOR site, freight included
- Returns
- Replacement of items damaged in transit within 7 days
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Transformer rating10 MVAKON-8E1-01 | Transformer rating: 10 MVA | 2 nos · 30-40 weeks | for verified buyers |
| Transformer rating20 MVAKON-8E1-02 | Transformer rating: 20 MVA | 2 nos · 30-40 weeks | for verified buyers |
| Transformer rating31.5 MVAKON-8E1-03 | Transformer rating: 31.5 MVA | 2 nos · 30-40 weeks | for verified buyers |
| Transformer rating50 MVAKON-8E1-04 | Transformer rating: 50 MVA | 2 nos · 30-40 weeks | for verified buyers |
Specifications
| Transformer rating | 10 MVA to 50 MVA (see variants) |
|---|---|
| Primary voltage | 132 kV |
| Secondary voltage | 11 kVmade to order: 33 kV |
| Chassis | Container |
| Primary switchgear | AIS disconnector and breaker |
| Secondary switchgear | Indoor VCB panel |
| Control and relay | Numerical relays |
| Fire protection | Detection and extinguisher |
| Auxiliary supply | DC battery + DG |
| Transport weight | Up to 45 t |
| Setup time | < 4 hours |
| Grounding | Mobile earthing kit |
| Cable reel | Included |