Catalogue / Hybrid & dead-tank switchgear
Dead-tank circuit breaker with CTs, Pro seriesSample
by Konkanparam Switchgear (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Konkanparam Switchgear (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
Dead-tank circuit breaker with CTs from Konkanparam, Pro series: 4 system voltage options between 72.5 kV and 420 kV. Design: fewer SF6 joints, ideal for pollution-prone sites and combines breaker, disconnector and CT. Typically used for brownfield bay additions, pollution and coastal areas and compact substations. Designed and tested to IEC 62271-100, IEC 62271-108 and IEC 62271-1. Lead time 16-24 weeks; delivers to East & North-East India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Konkanparam
- Model
- KON-FD6 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 1 nos
- Lead time
- 16-24 weeks
- Warranty
- 36 months
- Standards
- IEC 62271-100, IEC 62271-108, IEC 62271-1
- Delivers to
- East & North-East India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Wooden crate, seaworthy
- Delivery terms
- FOR site, freight included
- Returns
- Returns within 15 days if unused, in original packing
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| System voltage72.5 kVKON-FD6-01 | System voltage: 72.5 kV | 1 nos · 16-24 weeks | for verified buyers |
| System voltage145 kVKON-FD6-02 | System voltage: 145 kV | 1 nos · 16-24 weeks | for verified buyers |
| System voltage245 kVKON-FD6-03 | System voltage: 245 kV | 1 nos · 28-36 weeks | for verified buyers |
| System voltage420 kVKON-FD6-04 | System voltage: 420 kV | 1 nos · 28-36 weeks | for verified buyers |
Specifications
| System voltage | 72.5 kV to 420 kV (see variants) |
|---|---|
| Concept | Dead tank |
| Rated current | 4000 Amade to order: 2000 A / 3150 A |
| Breaking current | 50 kAmade to order: 31.5 kA / 40 kA |
| Gas | SF6 |
| Integrated CT | Yes, up to 5 cores |
| Integrated disconnector | Yesmade to order: No |
| Integrated earth switch | Yes |
| Mechanism | Motor springmade to order: Spring |
| Insulation | Air outdoor bushings |
| Footprint saving | 50-70% |
| Operating temp | -30 to 50 deg C |
| Monitoring | Gas density, operation counter |