Catalogue / Gas-insulated switchgear (GIS)
Compact GIS bay for substation, Ultra seriesSample
by Konkanparam Switchgear (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Konkanparam Switchgear (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
The Ultra range of compact GIS bay for substation by Konkanparam covers 4 system voltage options (36 kV to 245 kV). Key features: gas compartment with density monitors, factory-assembled bays and UHF partial discharge sensors. Typically used for metro rail traction, offshore and hilly regions and renewable pooling stations. Designed and tested to IEC 62271-203, IEC 62271-1 and IEC 62271-100. Lead time 40-52 weeks; delivers to East & North-East India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Konkanparam
- Model
- KON-7A9 series
- Listing type
- Product
- Unit
- bay
- Minimum order
- 1 bay
- Lead time
- 40-52 weeks
- Warranty
- 36 months
- Standards
- IEC 62271-203, IEC 62271-1, IEC 62271-100
- Delivers to
- East & North-East India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Wooden crate, seaworthy
- Delivery terms
- Ex-works, freight extra at actuals
- Returns
- Returns within 15 days if unused, in original packing
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| System voltage36 kVKON-7A9-01 | System voltage: 36 kV | 1 bay · 40-52 weeks | for verified buyers |
| System voltage72.5 kVKON-7A9-02 | System voltage: 72.5 kV | 1 bay · 40-52 weeks | for verified buyers |
| System voltage145 kVKON-7A9-03 | System voltage: 145 kV | 1 bay · 40-52 weeks | for verified buyers |
| System voltage245 kVKON-7A9-04 | System voltage: 245 kV | 1 bay · 40-52 weeks | for verified buyers |
Specifications
| System voltage | 36 kV to 245 kV (see variants) |
|---|---|
| Rated current | 2500 Amade to order: 1250 A / 3150 A / 4000 A |
| Short-circuit current | 50 kA |
| Configuration | Single busmade to order: Double bus / Ring bus |
| Enclosure | Aluminium alloymade to order: Steel |
| Gas | SF6/N2 mixmade to order: SF6 / Clean air |
| Bay width | 1200 mmmade to order: 800 mm / 2500 mm |
| Operating mechanism | Motormade to order: Spring |
| Partial discharge monitoring | UHF sensors |
| Control | Local control cubicle with BCU |
| Gas leakage | < 0.1% per year |
| Earth switches | Maintenance + fast acting |
| Interlocks | Mechanical and electrical |