Catalogue / Hydrogen sensors & safety systems
Electrochemical H2 sensor, Titan 7 seriesSample
by Konkanpushpak New Energy (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Konkanpushpak New Energy (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
The Titan 7 range of electrochemical H2 sensor by Konkanpushpak covers 3 detection range options (0-1000 ppm to 0-100% LEL). Highlights: hot swap sensor head, self-diagnostics and sensor fault alarm and interface with plant ESD. Suited to battery rooms, refineries and electrolyser plants. Designed and tested to IEC 60079-29-1, IEC 60079-0 and IEC 61508 (SIL 2). Lead time 2-4 weeks; delivers to All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Konkanpushpak
- Model
- KON-3E1 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 5 nos
- Lead time
- 2-4 weeks
- Warranty
- 24 months
- Standards
- IEC 60079-29-1, IEC 60079-0, IEC 61508 (SIL 2)
- Delivers to
- All India
- GST rate
- 18 %
- Country of origin
- India (imported sub-assemblies)
- Packaging
- Drum / reel with end caps
- Delivery terms
- Door delivery in metro cities
- Returns
- Replacement of items damaged in transit within 7 days
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Detection range0-1000 ppmKON-3E1-01 | Detection range: 0-1000 ppm | 5 nos · 2-4 weeks | for verified buyers |
| Detection range0-4% volKON-3E1-02 | Detection range: 0-4% vol | 5 nos · 2-4 weeks | for verified buyers |
| Detection range0-100% LELKON-3E1-03 | Detection range: 0-100% LEL | 5 nos · 2-4 weeks | for verified buyers |
Specifications
| Detection range | 0-1000 ppm to 0-100% LEL (see variants) |
|---|---|
| Sensor type | Catalytic bead |
| Output | Relay |
| Response time T90 | < 30 smade to order: < 10 s |
| Accuracy | +/- 5% of FSmade to order: +/- 2% of FS |
| Hazardous area | Ex d IIC T4made to order: Ex ia IIC T4 |
| Supply | 24 V DC |
| Ingress protection | IP65 |
| Housing | Aluminiummade to order: SS 316 |
| Operating temperature | -40 to 70 deg C |
| Calibration interval | 12 months |
| Alarm set points | 10% LELmade to order: 20% LEL |
| Sensor life | 3 years |