Catalogue / Electrical safety audits

No photo yet

Electrical safety audit of industrial plants, Core 3 seriesSample

by Krishna Infra Services (Sample) · verified by BARREL

Price for verified buyers

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Krishna Infra Services (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Register your company to see prices.

Electrical safety audit of industrial plants from Krishna, Core 3 series: 5 installed load options between 500 kVA and 25 MVA. Design: risk-ranked findings, compliance matrix against CEA safety rules and training recommendations for staff. Used by data centres, solar and wind sites and hospitals and commercial buildings. Delivered in line with Indian Electricity Act 2003, CEA (Measures relating to Safety) Regulations and IS 5216. Mobilisation Report in 7-14 days; serves All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Krishna
Model
KRI-688 series
Listing type
Service
Unit
site
Minimum order
1 site
Lead time
Report in 7-14 days
Warranty
Clarifications on report at no cost for 6 months
Standards
Indian Electricity Act 2003, CEA (Measures relating to Safety) Regulations, IS 5216
Delivers to
All India
GST rate
18 %
Country of origin
India (imported sub-assemblies)
Delivery terms
Site mobilisation as per work order
Returns
Re-work of defective scope at no cost
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Installed load500 kVAKRI-688-01Installed load: 500 kVA1 site · Report in 7-14 daysfor verified buyers
Installed load1 MVAKRI-688-02Installed load: 1 MVA1 site · Report in 7-14 daysfor verified buyers
Installed load5 MVAKRI-688-03Installed load: 5 MVA1 site · Report in 7-14 daysfor verified buyers
Installed load10 MVAKRI-688-04Installed load: 10 MVA1 site · Report in 7-14 daysfor verified buyers
Installed load25 MVAKRI-688-05Installed load: 25 MVA1 site · Report in 7-14 daysfor verified buyers

Specifications

Installed load500 kVA to 25 MVA (see variants)
ScopeAudit with arc-flash study
AuditorChartered engineer
MeasurementsEarth resistance, insulationmade to order: Thermography and power quality
ReportAction plan with timeline
Statutory recordsRegisters, test certificates, licencemade to order: Permit-to-work audit
SamplingRepresentative LV panelsmade to order: 100% of HV equipment
Follow-upRe-audit after 3 months
Turnaround1-2 weeksmade to order: 3-4 weeks
PresentationFindings to management
AccreditationISO/IEC 17020 body

BARREL: Bharat Atom Renewable Resources Energy Limited