Catalogue / Transformer overhaul & oil filtration

No photo yet

Power transformer overhaul and oil reconditioning, Xtra seriesSample

by Krishna Infra Services (Sample) · verified by BARREL

Price on quote

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Krishna Infra Services (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

The Xtra service of power transformer overhaul and oil reconditioning by Krishna covers 5 transformer rating options (1 MVA to 50 MVA). Design: core insulation resistance checks, leak testing before energisation and hot oil circulation under vacuum. Suited to captive power plants, solar and wind pooling substations and industrial distribution transformers. Delivered in line with IS 335 (Mineral Insulating Oil), IS 1866 (Oil Maintenance) and IEC 60422. Mobilisation Planned shutdown required; serves All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Krishna
Model
KRI-4C5 series
Listing type
Service
Unit
nos
Minimum order
1 nos
Lead time
Planned shutdown required
Warranty
Oil quality guarantee 6 months
Standards
IS 335 (Mineral Insulating Oil), IS 1866 (Oil Maintenance), IEC 60422
Delivers to
All India
GST rate
18 %
Country of origin
India
Delivery terms
Site mobilisation as per work order
Returns
Re-work of defective scope at no cost
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Transformer rating1 MVAKRI-4C5-01Transformer rating: 1 MVA1 nos · Planned shutdown requiredon quote
Transformer rating5 MVAKRI-4C5-02Transformer rating: 5 MVA1 nos · Planned shutdown requiredon quote
Transformer rating10 MVAKRI-4C5-03Transformer rating: 10 MVA1 nos · Planned shutdown requiredon quote
Transformer rating20 MVAKRI-4C5-04Transformer rating: 20 MVA1 nos · Planned shutdown requiredon quote
Transformer rating50 MVAKRI-4C5-05Transformer rating: 50 MVA1 nos · Planned shutdown requiredon quote

Specifications

Transformer rating1 MVA to 50 MVA (see variants)
ServiceInternal inspection and overhaulmade to order: Oil filtration and dehydration / Oil reclamation / Full overhaul with rewinding
Filtration machineVacuum dehydration 6000 L/hr
Oil BDV targetAbove 70 kV
Moisture targetBelow 10 ppmmade to order: Below 5 ppm
TestingDGA, furan, BDV, tan deltamade to order: Full routine tests after overhaul
SparesBushings and OLTC parts at cost
Downtime5-7 days
Site workHot oil circulation at site
Crew4 technicians with supervisor
CertificateOil test report from NABL labmade to order: Overhaul report with test data