Catalogue / MV metal-clad switchboards (11–33 kV)

No photo yet

Indoor MV switchgear panel with VCB, Xtra seriesSample

by Krishnaprithvi Switchgear (Sample) · verified by BARREL

Price on quote

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Krishnaprithvi Switchgear (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

The Xtra range of indoor MV switchgear panel with VCB by Krishnaprithvi covers 4 rating options (11 kV 1250 A to 33 kV 1250 A). Key features: type test reports from recognised labs, test facility for cable tests without isolating and earthing switch interlocked with breaker. Suited to steel and cement plants, renewable plant evacuation boards and grid substations 33/11 kV. Designed and tested to IEC 62271-200, IEC 62271-100 and IS 3427. Lead time 12-16 weeks; delivers to All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Krishnaprithvi
Model
KRI-B86 series
Listing type
Product
Unit
nos
Minimum order
1 nos
Lead time
12-16 weeks
Warranty
18 months from commissioning
Standards
IEC 62271-200, IEC 62271-100, IS 3427
Delivers to
All India
GST rate
18 %
Country of origin
India
Packaging
Steel skid with shrink wrap
Delivery terms
FOR site, freight included
Returns
Replacement of items damaged in transit within 7 days
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Rating11 kV 1250 AKRI-B86-01Rating: 11 kV 1250 A1 nos · 12-16 weekson quote
Rating11 kV 2500 AKRI-B86-02Rating: 11 kV 2500 A1 nos · 12-16 weekson quote
Rating22 kV 1250 AKRI-B86-03Rating: 22 kV 1250 A1 nos · 12-16 weekson quote
Rating33 kV 1250 AKRI-B86-04Rating: 33 kV 1250 A1 nos · 12-16 weekson quote

Specifications

Rating11 kV 1250 A to 33 kV 1250 A (see variants)
InsulationAir-insulated
Short-circuit rating25 kA/3 smade to order: 31.5 kA/3 s / 40 kA/3 s
Panel functionCapacitor bank feedermade to order: Incomer / Bus coupler / Outgoing feeder
BusbarDouble busbarmade to order: Single busbar
Internal arc ratingIAC AFLR 40 kA 1 s
Loss of service continuityLSC2Bmade to order: LSC2A
Partition classPM metallic partition
Auxiliary supply220 V DC
Protection relaysDirectional O/C
CommunicationIEC 60870-5-103made to order: IEC 61850 / Modbus RTU
Bus VTFixed
Degree of protectionIP4X

BARREL: Bharat Atom Renewable Resources Energy Limited