Catalogue / Compact secondary substations

No photo yet

Unitised substation (RMU, transformer, LT panel), Prime 5 seriesSample

by Kutchwatt Transformer Works (Sample) · verified by BARREL

Price for verified buyers

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Kutchwatt Transformer Works (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Register your company to see prices.

Unitised substation (RMU, transformer, LT panel) from Kutchwatt, Prime 5 series: 4 transformer rating options between 250 kVA and 1000 kVA. Highlights: factory assembled and tested, compact footprint for urban sites and oil sump and fire barriers. Used by solar power plants, housing complexes and urban distribution. Designed and tested to IEC 62271-202, IS 1180 and IEC 62271-200. Lead time 10-14 weeks; delivers to All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Kutchwatt
Model
KUT-9A8 series
Listing type
Product
Unit
nos
Minimum order
2 nos
Lead time
10-14 weeks
Warranty
24 months
Standards
IEC 62271-202, IS 1180, IEC 62271-200
Delivers to
All India and export (SAARC, Middle East, Africa)
GST rate
18 %
Country of origin
India (imported sub-assemblies)
Packaging
Corrugated box on pallet
Delivery terms
FOR site, freight included
Returns
Replacement of items damaged in transit within 7 days
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Transformer rating250 kVAKUT-9A8-01Transformer rating: 250 kVA2 nos · 10-14 weeksfor verified buyers
Transformer rating500 kVAKUT-9A8-02Transformer rating: 500 kVA2 nos · 10-14 weeksfor verified buyers
Transformer rating630 kVAKUT-9A8-03Transformer rating: 630 kVA2 nos · 10-14 weeksfor verified buyers
Transformer rating1000 kVAKUT-9A8-04Transformer rating: 1000 kVA2 nos · 10-14 weeksfor verified buyers

Specifications

Transformer rating250 kVA to 1000 kVA (see variants)
Primary voltage11 kV
Secondary voltage0.433 kVmade to order: 0.69 kV
HV equipmentFuse switchmade to order: Ring main unit / VCB panel
Transformer typeOil-immersedmade to order: Cast resin dry
LT sectionACB incomermade to order: MCCB feeders
EnclosureConcrete
Ingress protectionIP54
Internal arc rating16 kA 1 s
Short-circuit rating20 kAmade to order: 25 kA
MeteringMultifunction meter, CT operated
VentilationForced fan
Oil containmentIntegrated sump

BARREL: Bharat Atom Renewable Resources Energy Limited