Catalogue / Changeover switches & ATS panels
Manual changeover switch, Eco 6 seriesSample
by Lohacore Switchgear (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Lohacore Switchgear (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
Lohacore Eco 6 manual changeover switch, offered in 5 rating options from 400 A to 2500 A. Highlights: manual override for maintenance, programmable voltage and frequency sensing and genset auto-start and cool-down logic. Suited to telecom and industrial facilities, hospitals and data centres and commercial buildings with DG sets. Designed and tested to IEC 60947-6-1, IS/IEC 60947-3 and IS 8623 (Part 1). Lead time 1-2 weeks; delivers to East & North-East India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Lohacore
- Model
- LOH-2B4 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 1 nos
- Lead time
- 1-2 weeks
- Warranty
- 18 months from supply
- Standards
- IEC 60947-6-1, IS/IEC 60947-3, IS 8623 (Part 1)
- Delivers to
- East & North-East India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Drum / reel with end caps
- Delivery terms
- FOR site, freight included
- Returns
- Returns within 15 days if unused, in original packing
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Rating400 ALOH-2B4-01 | Rating: 400 A | 1 nos · 1-2 weeks | for verified buyers |
| Rating630 ALOH-2B4-02 | Rating: 630 A | 1 nos · 1-2 weeks | for verified buyers |
| Rating1000 ALOH-2B4-03 | Rating: 1000 A | 1 nos · 1-2 weeks | for verified buyers |
| Rating1600 ALOH-2B4-04 | Rating: 1600 A | 1 nos · 4-6 weeks | for verified buyers |
| Rating2500 ALOH-2B4-05 | Rating: 2500 A | 1 nos · 4-6 weeks | for verified buyers |
Specifications
| Rating | 400 A to 2500 A (see variants) |
|---|---|
| Type | Manual changeover |
| Poles | 3Pmade to order: 4P |
| Rated voltage | 415 V AC |
| Transfer device | Switch-disconnector |
| Transition | Openmade to order: Closed / Delayed |
| Controller | Microprocessor ATS controller |
| Transfer time | Under 3 s |
| Mains failure delay | Adjustable 0-60 s |
| Short-circuit withstand | 25 kAmade to order: 10 kA / 36 kA / 50 kA |
| Enclosure | IP54 sheet steel |
| Auxiliary supply | 24 V DC |
| Genset start signal | CAN / Modbus |