Catalogue / MV metal-clad switchboards (11–33 kV)
Gas-insulated MV switchgear panel, Edge seriesSample
by Lohacore Switchgear (Sample) · verified by BARREL
Price on quote
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Lohacore Switchgear (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
The Edge range of gas-insulated MV switchgear panel by Lohacore covers 5 rating options (11 kV 1250 A to 33 kV 2000 A). Highlights: earthing switch interlocked with breaker, arc-tested compartments with duct to outside and IEC 61850 communication for substation automation. Typically used for renewable plant evacuation boards, steel and cement plants and grid substations 33/11 kV. Designed and tested to IEC 62271-200, IEC 62271-100 and IS 3427. Lead time 8-10 weeks; delivers to East & North-East India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Lohacore
- Model
- LOH-363 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 1 nos
- Lead time
- 8-10 weeks
- Warranty
- 18 months from commissioning
- Standards
- IEC 62271-200, IEC 62271-100, IS 3427
- Delivers to
- East & North-East India
- GST rate
- 18 %
- Country of origin
- India (imported sub-assemblies)
- Packaging
- Steel skid with shrink wrap
- Delivery terms
- FOR nearest railhead
- Returns
- No returns on made-to-order items
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Rating11 kV 1250 ALOH-363-01 | Rating: 11 kV 1250 A | 1 nos · 8-10 weeks | on quote |
| Rating11 kV 2500 ALOH-363-02 | Rating: 11 kV 2500 A | 1 nos · 8-10 weeks | on quote |
| Rating22 kV 1250 ALOH-363-03 | Rating: 22 kV 1250 A | 1 nos · 8-10 weeks | on quote |
| Rating33 kV 1250 ALOH-363-04 | Rating: 33 kV 1250 A | 1 nos · 12-16 weeks | on quote |
| Rating33 kV 2000 ALOH-363-05 | Rating: 33 kV 2000 A | 1 nos · 12-16 weeks | on quote |
Specifications
| Rating | 11 kV 1250 A to 33 kV 2000 A (see variants) |
|---|---|
| Insulation | Air-insulated |
| Short-circuit rating | 40 kA/3 smade to order: 25 kA/3 s / 31.5 kA/3 s |
| Panel function | Capacitor bank feedermade to order: Incomer / Bus coupler / Outgoing feeder |
| Busbar | Double busbar |
| Internal arc rating | IAC AFLR 31.5 kA 1 s |
| Loss of service continuity | LSC2Bmade to order: LSC2A |
| Partition class | PM metallic partition |
| Auxiliary supply | 220 V DCmade to order: 110 V DC |
| Protection relays | Directional O/C |
| Communication | IEC 60870-5-103 |
| Bus VT | Withdrawable |
| Degree of protection | IP54made to order: IP4X |