Catalogue / Ring main units (RMU)

No photo yet

Extensible ring main unit with VCB, Plus 5 seriesSample

by Lonavala Panels (Sample) · verified by BARREL

Price for verified buyers

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Lonavala Panels (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Register your company to see prices.

Extensible ring main unit with VCB from Lonavala, Plus 5 series: 3 configuration options between 4-way (2LBS+LBS+VCB) and 5-way (3LBS+2VCB). Key features: cable test facility on front panel, internal arc tested for operator safety and sealed-for-life gas tank unaffected by humidity or dust. Typically used for urban 11 kV ring networks, discom compact substations and metro and airport distribution. Designed and tested to IEC 62271-200, IEC 62271-103 and IEC 62271-105. Lead time 4-6 weeks; delivers to All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Lonavala
Model
LON-5C4 series
Listing type
Product
Unit
nos
Minimum order
5 nos
Lead time
4-6 weeks
Warranty
12 months from commissioning
Standards
IEC 62271-200, IEC 62271-103, IEC 62271-105
Delivers to
All India and export (SAARC, Middle East, Africa)
GST rate
18 %
Country of origin
India
Packaging
As per item, transit-safe
Delivery terms
FOR nearest railhead
Returns
No returns on made-to-order items
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Configuration4-way (2LBS+LBS+VCB)LON-5C4-01Configuration: 4-way (2LBS+LBS+VCB)5 nos · 4-6 weeksfor verified buyers
Configuration4-way (3LBS+TF)LON-5C4-02Configuration: 4-way (3LBS+TF)5 nos · 4-6 weeksfor verified buyers
Configuration5-way (3LBS+2VCB)LON-5C4-03Configuration: 5-way (3LBS+2VCB)5 nos · 4-6 weeksfor verified buyers

Specifications

Configuration4-way (2LBS+LBS+VCB) to 5-way (3LBS+2VCB) (see variants)
Rated voltage36 kV
Rated current - ring400 A
Transformer feeder200 A fuse-switch
Short-circuit rating25 kA/3 s
Insulation mediumAir insulatedmade to order: SF6 gas / Solid dielectric
Switch typeDisconnector + earthing
ExtensibilityExtensible one side
Protection relaySelf-powered O/C-E/F relay
Fault passage indicatorOptional
EnclosureStainless steel gas tankmade to order: Mild steel RAL 7035
Degree of protectionIP54
Motor operatorNot fitted