Catalogue / Thermography & condition monitoring
Vibration and oil condition monitoring, Titan 7 seriesSample
by Maduraisurya Technical Services (Sample) · verified by BARREL
Price on quote
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Maduraisurya Technical Services (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Vibration and oil condition monitoring from Maduraisurya, Titan 7 series: 3 asset size options between 1 MW and 10 MW. Design: load condition recorded with each scan, trend data for repeated surveys and hotspot location tagged with GPS. Typically used for solar plants (module and string hotspots), industrial MCC panels and substation switchgear and transformers. Delivered in line with ISO 18434-1, IEC 62446-3 and IEEE 1584. Mobilisation Mobilisation in 3-7 days; serves All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Maduraisurya
- Model
- MAD-4E7 series
- Listing type
- Service
- Unit
- site
- Minimum order
- 1 site
- Lead time
- Mobilisation in 3-7 days
- Warranty
- Re-scan of repaired points at no cost
- Standards
- ISO 18434-1, IEC 62446-3, IEEE 1584
- Delivers to
- All India
- GST rate
- 18 %
- Country of origin
- India
- Delivery terms
- Site mobilisation as per work order
- Returns
- Re-work of defective scope at no cost
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Asset size1 MWMAD-4E7-01 | Asset size: 1 MW | 1 site · Mobilisation in 3-7 days | on quote |
| Asset size5 MWMAD-4E7-02 | Asset size: 5 MW | 1 site · Mobilisation in 3-7 days | on quote |
| Asset size10 MWMAD-4E7-03 | Asset size: 10 MW | 1 site · Mobilisation in 3-7 days | on quote |
Specifications
| Asset size | 1 MW to 10 MW (see variants) |
|---|---|
| Technique | Handheld thermography |
| Camera resolution | 1280x1024 radiometricmade to order: 640x480 radiometric |
| Deliverable | Annotated hotspot reportmade to order: CAT-wise severity ranking with fix actions |
| Drone services | Ground sampling 3 cm per pixelmade to order: Orthomosaic of full plant |
| Defect classification | Per client maintenance policy |
| Team | Level II thermographer plus pilot |
| Certification | Technicians with ASNT level IImade to order: ISO 18436-7 trained |
| Turnaround | Report in 10 daysmade to order: Report in 5 days |
| Frequency | One-timemade to order: Annual or bi-annual plan |
| Software | Cloud dashboard with trend history |