Catalogue / Power system studies (load flow, short circuit, grid code)
Dynamic stability and fault ride-through study, Prime seriesSample
by Magadh Engineering Services (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Magadh Engineering Services (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
Magadh Prime dynamic stability and fault ride-through study, offered in 5 network scale options from 33 kV plant to 400 kV system. Key features: PSS/E and PSCAD model support, reactive power capability curves and relay setting files ready to load. Typically used for utilities and consultants, renewable developers seeking connectivity and industrial plants adding generation. Delivered in line with CEA (Technical Standards for Connectivity) Regulations, Indian Electricity Grid Code and IEEE 1547. Mobilisation 2-6 weeks; serves North India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Magadh
- Model
- MAG-5E2 series
- Listing type
- Service
- Unit
- report
- Minimum order
- 1 report
- Lead time
- 2-6 weeks
- Warranty
- Clarifications to utility at no cost
- Standards
- CEA (Technical Standards for Connectivity) Regulations, Indian Electricity Grid Code, IEEE 1547
- Delivers to
- North India
- GST rate
- 18 %
- Country of origin
- India
- Delivery terms
- Site mobilisation as per work order
- Returns
- Re-work of defective scope at no cost
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Network scale33 kV plantMAG-5E2-01 | Network scale: 33 kV plant | 1 report · 2-6 weeks | for verified buyers |
| Network scale66 kV systemMAG-5E2-02 | Network scale: 66 kV system | 1 report · 2-6 weeks | for verified buyers |
| Network scale132 kV systemMAG-5E2-03 | Network scale: 132 kV system | 1 report · 2-6 weeks | for verified buyers |
| Network scale220 kV systemMAG-5E2-04 | Network scale: 220 kV system | 1 report · 2-6 weeks | for verified buyers |
| Network scale400 kV systemMAG-5E2-05 | Network scale: 400 kV system | 1 report · 2-6 weeks | for verified buyers |
Specifications
| Network scale | 33 kV plant to 400 kV system (see variants) |
|---|---|
| Study type | Dynamic and transientmade to order: Load flow and short circuit / Harmonics / Protection coordination |
| Software | PSS/E |
| Model data | Utility network model |
| Deliverables | Study report with resultsmade to order: Model files and relay settings |
| Grid code checks | Voltage and reactive power capability |
| Review | Utility submission supportmade to order: Lender review |
| Scenarios | Normal and N-1 |
| Team | Power system engineer |
| Turnaround | 2-3 weeksmade to order: 4-6 weeks |
| Validation | Compared with measured datamade to order: Peer review |