Catalogue / Substation & line O&M
Substation O&M with 24x7 shift operation, Duo seriesSample
by Magadh Logistics (Sample) · verified by BARREL
Price on quote
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Magadh Logistics (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Magadh Duo substation O&M with 24x7 shift operation, offered in 6 voltage level options from 11 kV to 400 kV. Highlights: insulator and joint inspection, outage planning with the utility and permit-to-work and lockout-tagout. Typically used for railway and metro sub-stations, state utility outsourcing and industrial captive substations. Delivered in line with CEA (Measures relating to Safety) Regulations, CEA (Grid Standards) Regulations and IS 10028 (Transformer Installation). Mobilisation Mobilisation in 2-3 weeks; serves All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Magadh
- Model
- MAG-0A7 series
- Listing type
- Service
- Unit
- month
- Minimum order
- 1 month
- Lead time
- Mobilisation in 2-3 weeks
- Warranty
- Service credits for avoidable outages
- Standards
- CEA (Measures relating to Safety) Regulations, CEA (Grid Standards) Regulations, IS 10028 (Transformer Installation)
- Delivers to
- All India and export (SAARC, Middle East, Africa)
- GST rate
- 18 %
- Country of origin
- India
- Delivery terms
- Site mobilisation as per work order
- Returns
- Re-work of defective scope at no cost
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Voltage level11 kVMAG-0A7-01 | Voltage level: 11 kV | 1 month · Mobilisation in 2-3 weeks | on quote |
| Voltage level33 kVMAG-0A7-02 | Voltage level: 33 kV | 1 month · Mobilisation in 2-3 weeks | on quote |
| Voltage level66 kVMAG-0A7-03 | Voltage level: 66 kV | 1 month · Mobilisation in 2-3 weeks | on quote |
| Voltage level132 kVMAG-0A7-04 | Voltage level: 132 kV | 1 month · Mobilisation in 2-3 weeks | on quote |
| Voltage level220 kVMAG-0A7-05 | Voltage level: 220 kV | 1 month · Baseline condition audit first | on quote |
| Voltage level400 kVMAG-0A7-06 | Voltage level: 400 kV | 1 month · Baseline condition audit first | on quote |
Specifications
| Voltage level | 11 kV to 400 kV (see variants) |
|---|---|
| Scope | Maintenance only |
| Shift pattern | General shift plus on-callmade to order: 3 shifts, 24x7 |
| Manpower | Two engineers plus 12 staffmade to order: Engineer plus 6 operators |
| Line patrolling | Monthly foot patrol |
| Testing | Annual relay and CT/PT test |
| Statutory records | Log books, permits, shutdown registermade to order: CEIG renewal support |
| Spares | Consumables includedmade to order: Critical spares by owner |
| Response time | 2 hours for trip |
| Reporting | Monthly fault and maintenance reportmade to order: Real-time dashboards |
| Term | 3 years |