Power transformer overhaul and oil reconditioning, Plus seriesSample

by Magadh Logistics (Sample) · verified by BARREL

Price on quote

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Magadh Logistics (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Magadh Plus power transformer overhaul and oil reconditioning, offered in 4 transformer rating options from 5 MVA to 50 MVA. Design: oil sampling and DGA before work, nitrogen or dry air purge on opening and leak testing before energisation. Suited to industrial distribution transformers, solar and wind pooling substations and captive power plants. Delivered in line with IS 335 (Mineral Insulating Oil), IS 1866 (Oil Maintenance) and IEC 60422. Mobilisation Mobilisation in 3-5 days; serves All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Magadh
Model
MAG-4C2 series
Listing type
Service
Unit
nos
Minimum order
1 nos
Lead time
Mobilisation in 3-5 days
Warranty
Workmanship 12 months
Standards
IS 335 (Mineral Insulating Oil), IS 1866 (Oil Maintenance), IEC 60422
Delivers to
All India and export (SAARC, Middle East, Africa)
GST rate
18 %
Country of origin
India
Delivery terms
Site mobilisation as per work order
Returns
Re-work of defective scope at no cost
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Transformer rating5 MVAMAG-4C2-01Transformer rating: 5 MVA1 nos · Mobilisation in 3-5 dayson quote
Transformer rating10 MVAMAG-4C2-02Transformer rating: 10 MVA1 nos · Mobilisation in 3-5 dayson quote
Transformer rating20 MVAMAG-4C2-03Transformer rating: 20 MVA1 nos · Planned shutdown requiredon quote
Transformer rating50 MVAMAG-4C2-04Transformer rating: 50 MVA1 nos · Planned shutdown requiredon quote

Specifications

Transformer rating5 MVA to 50 MVA (see variants)
ServiceFull overhaul with rewinding
Filtration machineMobile 12000 L/hr
Oil BDV targetAbove 70 kVmade to order: Above 60 kV
Moisture targetBelow 10 ppmmade to order: Below 5 ppm
TestingFull routine tests after overhaulmade to order: DGA, furan, BDV, tan delta
SparesGaskets and silica gel
Downtime2-3 daysmade to order: 5-7 days / 3-4 weeks
Site workHot oil circulation at site
Crew4 technicians with supervisormade to order: Specialised overhaul team
CertificateOil test report from NABL lab