Catalogue / Power system studies (load flow, short circuit, grid code)
Harmonic and power quality study, Volt seriesSample
by Magadh Technical Services (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Magadh Technical Services (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
Harmonic and power quality study from Magadh, Volt series: 5 network scale options between 33 kV plant and 400 kV system. Highlights: relay setting files ready to load, reactive power capability curves and PSS/E and PSCAD model support. Used by BESS integrators, renewable developers seeking connectivity and utilities and consultants. Delivered in line with CEA (Technical Standards for Connectivity) Regulations, Indian Electricity Grid Code and IEEE 1547. Mobilisation Kick-off in 1 week; serves All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Magadh
- Model
- MAG-4B9 series
- Listing type
- Service
- Unit
- report
- Minimum order
- 1 report
- Lead time
- Kick-off in 1 week
- Warranty
- Clarifications to utility at no cost
- Standards
- CEA (Technical Standards for Connectivity) Regulations, Indian Electricity Grid Code, IEEE 1547
- Delivers to
- All India and export (SAARC, Middle East, Africa)
- GST rate
- 18 %
- Country of origin
- India
- Delivery terms
- Site mobilisation as per work order
- Returns
- Re-work of defective scope at no cost
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Network scale33 kV plantMAG-4B9-01 | Network scale: 33 kV plant | 1 report · Kick-off in 1 week | for verified buyers |
| Network scale66 kV systemMAG-4B9-02 | Network scale: 66 kV system | 1 report · Kick-off in 1 week | for verified buyers |
| Network scale132 kV systemMAG-4B9-03 | Network scale: 132 kV system | 1 report · Kick-off in 1 week | for verified buyers |
| Network scale220 kV systemMAG-4B9-04 | Network scale: 220 kV system | 1 report · 2-6 weeks | for verified buyers |
| Network scale400 kV systemMAG-4B9-05 | Network scale: 400 kV system | 1 report · 2-6 weeks | for verified buyers |
Specifications
| Network scale | 33 kV plant to 400 kV system (see variants) |
|---|---|
| Study type | Load flow and short circuit |
| Software | DIgSILENT PowerFactory |
| Model data | Utility network model |
| Deliverables | Model files and relay settingsmade to order: Study report with results |
| Grid code checks | Voltage and reactive power capability |
| Review | Utility submission support |
| Scenarios | Normal and N-1 |
| Team | Lead plus modelling specialist |
| Turnaround | 4-6 weeksmade to order: 2-3 weeks |
| Validation | Peer reviewmade to order: Compared with measured data |