Catalogue / Testing & commissioning

No photo yet

Substation commissioning with CEIG inspection, Xtra seriesSample

by Mahabaleshwarflux Engineering Services (Sample) · verified by BARREL

Price on quote

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Mahabaleshwarflux Engineering Services (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

The Xtra service of substation commissioning with CEIG inspection by Mahabaleshwarflux covers 3 plant capacity options (50 MW to 250 MW). Design: test formats agreed before mobilisation, handover training to O&M team and thermography of terminations before charging. Suited to DISCOM and STU charging, repowering projects and EPC handover to owners. Delivered in line with IEC 62446-1, IEC 61724-1 and CEA (Technical Standards for Connectivity) Regulations. Mobilisation Mobilisation in 5 days; serves All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Mahabaleshwarflux
Model
MAH-B95 series
Listing type
Service
Unit
MW
Minimum order
1 MW
Lead time
Mobilisation in 5 days
Warranty
As per contract
Standards
IEC 62446-1, IEC 61724-1, CEA (Technical Standards for Connectivity) Regulations
Delivers to
All India
GST rate
18 %
Country of origin
India
Delivery terms
Site mobilisation as per work order
Returns
Re-work of defective scope at no cost
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Plant capacity50 MWMAH-B95-01Plant capacity: 50 MW1 MW · Mobilisation in 5 dayson quote
Plant capacity100 MWMAH-B95-02Plant capacity: 100 MW1 MW · Mobilisation in 5 dayson quote
Plant capacity250 MWMAH-B95-03Plant capacity: 250 MW1 MW · Mobilisation in 5 dayson quote

Specifications

Plant capacity50 MW to 250 MW (see variants)
Tests coveredTransformer, switchgear, relay tests
InstrumentsRelay test set, thermal camera
CalibrationCalibration valid at test date
TeamCommissioning engineer plus 2 testersmade to order: Lead plus 5 member crew
Statutory supportDISCOM charging supportmade to order: CEIG inspection coordination
ReportsTest reports with signed formats
Duration on site3-4 weeksmade to order: 5-7 days / 10-14 days
Performance guarantee testCapacity and PR test per contract
Grid code checksNot included
PaymentMilestone on energisationmade to order: 50% on start, 50% on report

BARREL: Bharat Atom Renewable Resources Energy Limited