Catalogue / Substation construction
33/132 kV AIS substation construction, Smart seriesSample
by Mahabaleshwarflux Engineering Services (Sample) · verified by BARREL
Price on quote
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Mahabaleshwarflux Engineering Services (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
The Smart service of 33/132 kV AIS substation construction by Mahabaleshwarflux covers 4 voltage class options (11 kV to 132 kV). Highlights: earth grid designed for fault level and soil resistivity, full documentation pack and as-built and battery and DC system installation. Typically used for industrial captive substations, data centre power infrastructure and state utility augmentation. Delivered in line with CEA (Technical Standards for Construction of Electrical Plants) Regulations, IEC 61936-1 and IS 3043 (Earthing). Mobilisation Engineering in 4-6 weeks; serves All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Mahabaleshwarflux
- Model
- MAH-363 series
- Listing type
- Service
- Unit
- bay
- Minimum order
- 1 bay
- Lead time
- Engineering in 4-6 weeks
- Warranty
- Defect liability 24 months
- Standards
- CEA (Technical Standards for Construction of Electrical Plants) Regulations, IEC 61936-1, IS 3043 (Earthing)
- Delivers to
- All India
- GST rate
- 18 %
- Country of origin
- India
- Delivery terms
- Site mobilisation as per work order
- Returns
- Re-work of defective scope at no cost
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Voltage class11 kVMAH-363-01 | Voltage class: 11 kV | 1 bay · Engineering in 4-6 weeks | on quote |
| Voltage class33 kVMAH-363-02 | Voltage class: 33 kV | 1 bay · Engineering in 4-6 weeks | on quote |
| Voltage class66 kVMAH-363-03 | Voltage class: 66 kV | 1 bay · Execution 6-15 months | on quote |
| Voltage class132 kVMAH-363-04 | Voltage class: 132 kV | 1 bay · Execution 6-15 months | on quote |
Specifications
| Voltage class | 11 kV to 132 kV (see variants) |
|---|---|
| Type | Hybrid GIS |
| Scope | Erection and testing |
| Transformers | Up to 50 MVAmade to order: Up to 160 MVA / Up to 315 MVA |
| Earthing | GI flat grid with ground rods |
| Bay count | 6-10 baysmade to order: 2-4 bays |
| Protection scheme | Numerical busbar protection |
| SCADA and communication | IEC 61850 compliant |
| Statutory | STU charging approval |
| Duration | 6-9 monthsmade to order: 12-15 months |
| Payment terms | Percentage on supply, erection |