Power transformer overhaul and oil reconditioning from Mahanadiparam, Flex series: 5 transformer rating options between 10 MVA and 315 MVA. Design: post-work tan delta and ratio tests, leak testing before energisation and hot oil circulation under vacuum. Typically used for captive power plants, solar and wind pooling substations and industrial distribution transformers. Delivered in line with IS 335 (Mineral Insulating Oil), IS 1866 (Oil Maintenance) and IEC 60422. Mobilisation Planned shutdown required; serves West India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Mahanadiparam
Model
MAH-4C6 series
Listing type
Service
Unit
nos
Minimum order
1 nos
Lead time
Planned shutdown required
Warranty
Workmanship 12 months
Standards
IS 335 (Mineral Insulating Oil), IS 1866 (Oil Maintenance), IEC 60422
Delivers to
West India
GST rate
18 %
Country of origin
India
Delivery terms
Site mobilisation as per work order
Returns
Re-work of defective scope at no cost
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Transformer rating10 MVAMAH-4C6-01Transformer rating: 10 MVA1 nos · Planned shutdown requiredfor verified buyers
Transformer rating20 MVAMAH-4C6-02Transformer rating: 20 MVA1 nos · Planned shutdown requiredfor verified buyers
Transformer rating50 MVAMAH-4C6-03Transformer rating: 50 MVA1 nos · Planned shutdown requiredfor verified buyers
Transformer rating100 MVAMAH-4C6-04Transformer rating: 100 MVA1 nos · Planned shutdown requiredfor verified buyers
Transformer rating315 MVAMAH-4C6-05Transformer rating: 315 MVA1 nos · Planned shutdown requiredfor verified buyers

Specifications

Transformer rating10 MVA to 315 MVA (see variants)
ServiceOil reclamation
Filtration machineVacuum dehydration 6000 L/hrmade to order: Mobile 12000 L/hr
Oil BDV targetAbove 60 kVmade to order: Above 70 kV
Moisture targetBelow 10 ppm
TestingFull routine tests after overhaul
SparesGaskets and silica gel
Downtime5-7 days
Site workWorkshop repairmade to order: Hot oil circulation at site
Crew4 technicians with supervisor
CertificateOverhaul report with test data