Catalogue / Thermography & condition monitoring
Online partial discharge and UV corona inspection, Prime seriesSample
by Mahanadiparam Technical Services (Sample) · verified by BARREL
Price on quote
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Mahanadiparam Technical Services (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Mahanadiparam Prime online partial discharge and UV corona inspection, offered in 3 asset size options from 10 MW to 50 MW. Design: re-scan after repair included, trend data for repeated surveys and hotspot location tagged with GPS. Used by industrial MCC panels, solar plants (module and string hotspots) and wind turbine electrical systems. Delivered in line with ISO 18434-1, IEC 62446-3 and IEEE 1584. Mobilisation Report in 5-10 days; serves West India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Mahanadiparam
- Model
- MAH-B25 series
- Listing type
- Service
- Unit
- site
- Minimum order
- 1 site
- Lead time
- Report in 5-10 days
- Warranty
- Report accuracy as per method
- Standards
- ISO 18434-1, IEC 62446-3, IEEE 1584
- Delivers to
- West India
- GST rate
- 18 %
- Country of origin
- India
- Delivery terms
- Site mobilisation as per work order
- Returns
- Re-work of defective scope at no cost
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Asset size10 MWMAH-B25-01 | Asset size: 10 MW | 1 site · Report in 5-10 days | on quote |
| Asset size25 MWMAH-B25-02 | Asset size: 25 MW | 1 site · Report in 5-10 days | on quote |
| Asset size50 MWMAH-B25-03 | Asset size: 50 MW | 1 site · Report in 5-10 days | on quote |
Specifications
| Asset size | 10 MW to 50 MW (see variants) |
|---|---|
| Technique | Partial discharge testingmade to order: Handheld thermography / Drone thermal imaging / Vibration analysis |
| Camera resolution | 640x480 radiometric |
| Deliverable | Annotated hotspot reportmade to order: CAT-wise severity ranking with fix actions |
| Drone services | Orthomosaic of full plant |
| Defect classification | Per client maintenance policy |
| Team | Level II thermographermade to order: Level II thermographer plus pilot |
| Certification | ISO 18436-7 trainedmade to order: Technicians with ASNT level II |
| Turnaround | Report in 5 days |
| Frequency | One-timemade to order: Annual or bi-annual plan |
| Software | Cloud dashboard with trend historymade to order: Analyser software with thermal library |