Catalogue / Substation & line O&M
Power transformer routine checks, Neo seriesSample
by Mahanadiparam Technical Services (Sample) · verified by BARREL
Price on quote
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Mahanadiparam Technical Services (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Mahanadiparam Neo power transformer routine checks, offered in 3 voltage level options from 11 kV to 66 kV. Design: insulator and joint inspection, permit-to-work and lockout-tagout and outage planning with the utility. Typically used for renewable pooling substations, industrial captive substations and state utility outsourcing. Delivered in line with CEA (Measures relating to Safety) Regulations, CEA (Grid Standards) Regulations and IS 10028 (Transformer Installation). Mobilisation Baseline condition audit first; serves West India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Mahanadiparam
- Model
- MAH-058 series
- Listing type
- Service
- Unit
- month
- Minimum order
- 1 month
- Lead time
- Baseline condition audit first
- Warranty
- As per contract
- Standards
- CEA (Measures relating to Safety) Regulations, CEA (Grid Standards) Regulations, IS 10028 (Transformer Installation)
- Delivers to
- West India
- GST rate
- 18 %
- Country of origin
- India
- Delivery terms
- Site mobilisation as per work order
- Returns
- Re-work of defective scope at no cost
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Voltage level11 kVMAH-058-01 | Voltage level: 11 kV | 1 month · Baseline condition audit first | on quote |
| Voltage level33 kVMAH-058-02 | Voltage level: 33 kV | 1 month · Baseline condition audit first | on quote |
| Voltage level66 kVMAH-058-03 | Voltage level: 66 kV | 1 month · Baseline condition audit first | on quote |
Specifications
| Voltage level | 11 kV to 66 kV (see variants) |
|---|---|
| Scope | Operation and maintenance |
| Shift pattern | 3 shifts, 24x7 |
| Manpower | Engineer plus 6 operators |
| Line patrolling | Monthly foot patrol |
| Testing | Thermography twice a yearmade to order: Annual relay and CT/PT test |
| Statutory records | CEIG renewal supportmade to order: Log books, permits, shutdown register |
| Spares | Consumables included |
| Response time | 2 hours for tripmade to order: 4 hours |
| Reporting | Real-time dashboardsmade to order: Monthly fault and maintenance report |
| Term | 3 years |