Catalogue / SF6 circuit breakers
Three-pole gang operated breaker, Titan 9 seriesSample
by Malabarojas HV Switchgear (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Malabarojas HV Switchgear (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
Malabarojas Titan 9 three-pole gang operated breaker, offered in 6 system voltage options from 36 kV to 800 kV. Design: type tested at KEMA or CPRI, density monitor with two stage alarm and corrosion-proof control cabinet. Suited to grid substations, industrial EHV supply and transmission lines. Designed and tested to IEC 62271-100, IS 13118 and IEC 62271-1. Lead time 12-16 weeks; delivers to West India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Malabarojas
- Model
- MAL-CD4 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 2 nos
- Lead time
- 12-16 weeks
- Warranty
- 24 months from commissioning
- Standards
- IEC 62271-100, IS 13118, IEC 62271-1
- Delivers to
- West India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Steel skid with shrink wrap
- Delivery terms
- FOR site, freight included
- Returns
- No returns on made-to-order items
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| System voltage36 kVMAL-CD4-01 | System voltage: 36 kV | 2 nos · 12-16 weeks | for verified buyers |
| System voltage72.5 kVMAL-CD4-02 | System voltage: 72.5 kV | 2 nos · 12-16 weeks | for verified buyers |
| System voltage145 kVMAL-CD4-03 | System voltage: 145 kV | 2 nos · 12-16 weeks | for verified buyers |
| System voltage245 kVMAL-CD4-04 | System voltage: 245 kV | 2 nos · 12-16 weeks | for verified buyers |
| System voltage420 kVMAL-CD4-05 | System voltage: 420 kV | 2 nos · 24-30 weeks | for verified buyers |
| System voltage800 kVMAL-CD4-06 | System voltage: 800 kV | 2 nos · 24-30 weeks | for verified buyers |
Specifications
| System voltage | 36 kV to 800 kV (see variants) |
|---|---|
| Rated current | 3150 A |
| Breaking current | 40 kA |
| Operating mechanism | Spring-spring |
| Operation | 3-polemade to order: Single-pole |
| Interrupter | Single break |
| SF6 pressure | 0.6 MPa abs |
| Duty cycle | O-0.3s-CO-3min-CO |
| Close time | < 60 ms |
| Insulator | Composite |
| Auxiliary supply | 220 V DC |
| Creepage | 25 mm/kV |
| Mechanical endurance | M2 |