Catalogue / Isolators & earth switches
Double-break isolator, Flex seriesSample
by Malabarojas HV Switchgear (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Malabarojas HV Switchgear (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
Malabarojas Flex double-break isolator, offered in 3 system voltage options from 12 kV to 72.5 kV. Key features: mechanical interlock with earth switch, corrosion-resistant galvanising and aux contacts for position indication. Used by captive plants, solar plant evacuation and railway traction. Designed and tested to IEC 62271-102, IS 9921 and IEC 62271-1. Lead time 6-8 weeks; delivers to West India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Malabarojas
- Model
- MAL-1C9 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 5 nos
- Lead time
- 6-8 weeks
- Warranty
- 30 months from supply
- Standards
- IEC 62271-102, IS 9921, IEC 62271-1
- Delivers to
- West India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Corrugated box on pallet
- Delivery terms
- Ex-works, freight extra at actuals
- Returns
- Replacement of items damaged in transit within 7 days
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| System voltage12 kVMAL-1C9-01 | System voltage: 12 kV | 5 nos · 6-8 weeks | for verified buyers |
| System voltage36 kVMAL-1C9-02 | System voltage: 36 kV | 5 nos · 6-8 weeks | for verified buyers |
| System voltage72.5 kVMAL-1C9-03 | System voltage: 72.5 kV | 5 nos · 6-8 weeks | for verified buyers |
Specifications
| System voltage | 12 kV to 72.5 kV (see variants) |
|---|---|
| Rated current | 4000 Amade to order: 800 A / 1250 A / 2000 A |
| Type | Double breakmade to order: Centre rotating / Pantograph / Vertical break |
| Earth switch | Withoutmade to order: With 1 earth switch / With 2 earth switches |
| Short-time current | 50 kAmade to order: 25 kA / 31.5 kA |
| Operation | Motor + manualmade to order: Manual |
| Insulators | Polymermade to order: Porcelain |
| Contact material | Silver-plated copper |
| Terminal | Aluminium flat pad |
| Mounting | Vertical |
| Control voltage | 110 V DC |
| Finish | Hot-dip galvanised |
| Peak withstand | 125 kA |