Catalogue / Gas-insulated switchgear (GIS)
Three-phase encapsulated GIS, Volt 6 seriesSample
by Malabarojas HV Switchgear (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Malabarojas HV Switchgear (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
The Volt 6 range of three-phase encapsulated GIS by Malabarojas covers 3 system voltage options (145 kV to 420 kV). Highlights: compact footprint, up to 90% saving, factory-assembled bays and maintenance-free enclosed design. Typically used for industrial plants, metro rail traction and offshore and hilly regions. Designed and tested to IEC 62271-203, IEC 62271-1 and IEC 62271-100. Lead time 40-52 weeks; delivers to West India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Malabarojas
- Model
- MAL-AC5 series
- Listing type
- Product
- Unit
- bay
- Minimum order
- 1 bay
- Lead time
- 40-52 weeks
- Warranty
- 24 months
- Standards
- IEC 62271-203, IEC 62271-1, IEC 62271-100
- Delivers to
- West India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Corrugated box on pallet
- Delivery terms
- FOR site, freight included
- Returns
- Replacement of items damaged in transit within 7 days
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| System voltage145 kVMAL-AC5-01 | System voltage: 145 kV | 1 bay · 40-52 weeks | for verified buyers |
| System voltage245 kVMAL-AC5-02 | System voltage: 245 kV | 1 bay · 40-52 weeks | for verified buyers |
| System voltage420 kVMAL-AC5-03 | System voltage: 420 kV | 1 bay · 40-52 weeks | for verified buyers |
Specifications
| System voltage | 145 kV to 420 kV (see variants) |
|---|---|
| Rated current | 3150 Amade to order: 1250 A / 2500 A / 4000 A |
| Short-circuit current | 50 kAmade to order: 31.5 kA / 40 kA |
| Configuration | Double busmade to order: Single bus / Ring bus |
| Enclosure | Aluminium alloy |
| Gas | Clean airmade to order: SF6 / SF6/N2 mix |
| Bay width | 2500 mmmade to order: 800 mm / 1200 mm |
| Operating mechanism | Motormade to order: Spring |
| Partial discharge monitoring | UHF sensors |
| Control | Local control cubicle with BCU |
| Gas leakage | < 0.1% per year |
| Earth switches | Maintenance + fast acting |
| Interlocks | Mechanical and electrical |