Catalogue / SF6 circuit breakers
Three-pole gang operated breaker, Edge 6 seriesSample
by Malabarojas HV Switchgear (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Malabarojas HV Switchgear (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
Malabarojas Edge 6 three-pole gang operated breaker, offered in 5 system voltage options from 36 kV to 420 kV. Highlights: type tested at KEMA or CPRI, self-blast or puffer interrupter and density monitor with two stage alarm. Typically used for generator bays, grid substations and transmission lines. Designed and tested to IEC 62271-100, IS 13118 and IEC 62271-1. Lead time 12-16 weeks; delivers to West India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Malabarojas
- Model
- MAL-CD6 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 1 nos
- Lead time
- 12-16 weeks
- Warranty
- 30 months from supply
- Standards
- IEC 62271-100, IS 13118, IEC 62271-1
- Delivers to
- West India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- As per item, transit-safe
- Delivery terms
- FOR site, freight included
- Returns
- Replacement of items damaged in transit within 7 days
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| System voltage36 kVMAL-CD6-01 | System voltage: 36 kV | 1 nos · 12-16 weeks | for verified buyers |
| System voltage72.5 kVMAL-CD6-02 | System voltage: 72.5 kV | 1 nos · 12-16 weeks | for verified buyers |
| System voltage145 kVMAL-CD6-03 | System voltage: 145 kV | 1 nos · 12-16 weeks | for verified buyers |
| System voltage245 kVMAL-CD6-04 | System voltage: 245 kV | 1 nos · 24-30 weeks | for verified buyers |
| System voltage420 kVMAL-CD6-05 | System voltage: 420 kV | 1 nos · 24-30 weeks | for verified buyers |
Specifications
| System voltage | 36 kV to 420 kV (see variants) |
|---|---|
| Rated current | 2000 Amade to order: 1250 A / 3150 A / 4000 A |
| Breaking current | 31.5 kAmade to order: 25 kA / 40 kA / 50 kA |
| Operating mechanism | Hydraulic springmade to order: Spring-spring |
| Operation | 3-pole |
| Interrupter | Two breaks |
| SF6 pressure | 0.6 MPa abs |
| Duty cycle | O-0.3s-CO-3min-CO |
| Close time | < 100 ms |
| Insulator | Porcelainmade to order: Composite |
| Auxiliary supply | 220 V DC |
| Creepage | 31 mm/kVmade to order: 25 mm/kV |
| Mechanical endurance | M2 |