Catalogue / Electrical safety audits

No photo yet

Fire and arc-flash risk assessment, Prime seriesSample

by Malwavolt Technical Services (Sample) · verified by BARREL

Price for verified buyers

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Malwavolt Technical Services (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Register your company to see prices.

Fire and arc-flash risk assessment from Malwavolt, Prime series: 4 installed load options between 1 MVA and 25 MVA. Key features: training recommendations for staff, fire exit and detection checks and risk-ranked findings. Used by solar and wind sites, manufacturing plants and data centres. Delivered in line with Indian Electricity Act 2003, CEA (Measures relating to Safety) Regulations and IS 5216. Mobilisation Report in 7-14 days; serves All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Malwavolt
Model
MAL-2D5 series
Listing type
Service
Unit
site
Minimum order
1 site
Lead time
Report in 7-14 days
Warranty
Clarifications on report at no cost for 6 months
Standards
Indian Electricity Act 2003, CEA (Measures relating to Safety) Regulations, IS 5216
Delivers to
All India and export (SAARC, Middle East, Africa)
GST rate
18 %
Country of origin
India
Delivery terms
Site mobilisation as per work order
Returns
Re-work of defective scope at no cost
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Installed load1 MVAMAL-2D5-01Installed load: 1 MVA1 site · Report in 7-14 daysfor verified buyers
Installed load5 MVAMAL-2D5-02Installed load: 5 MVA1 site · Report in 7-14 daysfor verified buyers
Installed load10 MVAMAL-2D5-03Installed load: 10 MVA1 site · Report in 7-14 daysfor verified buyers
Installed load25 MVAMAL-2D5-04Installed load: 25 MVA1 site · Report in 7-14 daysfor verified buyers

Specifications

Installed load1 MVA to 25 MVA (see variants)
ScopeAudit with arc-flash studymade to order: Visual and documentation audit / Audit with measurements
AuditorChartered engineermade to order: CEA-licensed engineer
MeasurementsThermography and power qualitymade to order: Earth resistance, insulation
ReportFindings with risk ratingmade to order: Action plan with timeline
Statutory recordsRegisters, test certificates, licence
Sampling100% of HV equipment
Follow-upClose-out verificationmade to order: Re-audit after 3 months
Turnaround1-2 weeksmade to order: 3-4 weeks
PresentationFindings to managementmade to order: Report only
AccreditationGovernment recognised agencymade to order: ISO/IEC 17020 body

BARREL: Bharat Atom Renewable Resources Energy Limited