Catalogue / Switchgear & breaker spares
Vacuum interrupter, Flex seriesSample
by Marwar Metal Industries (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Marwar Metal Industries (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
The Flex range of vacuum interrupter by Marwar covers 6 rated voltage options (12 kV to 145 kV). Design: complete overhaul kits available, interchangeable with original design and routine tested before dispatch. Used by utility maintenance, breaker retrofitting and planned overhauls. Designed and tested to IEC 62271-100, IEC 62271-102 and IS 13118. Lead time 4-8 weeks; delivers to East & North-East India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Marwar
- Model
- MAR-ED4 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 1 nos
- Lead time
- 4-8 weeks
- Warranty
- 12 months from supply
- Standards
- IEC 62271-100, IEC 62271-102, IS 13118
- Delivers to
- East & North-East India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- As per item, transit-safe
- Delivery terms
- FOR site, freight included
- Returns
- Replacement of items damaged in transit within 7 days
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Rated voltage12 kVMAR-ED4-01 | Rated voltage: 12 kV | 1 nos · 4-8 weeks | for verified buyers |
| Rated voltage17.5 kVMAR-ED4-02 | Rated voltage: 17.5 kV | 1 nos · 4-8 weeks | for verified buyers |
| Rated voltage24 kVMAR-ED4-03 | Rated voltage: 24 kV | 1 nos · 4-8 weeks | for verified buyers |
| Rated voltage36 kVMAR-ED4-04 | Rated voltage: 36 kV | 1 nos · 4-8 weeks | for verified buyers |
| Rated voltage72.5 kVMAR-ED4-05 | Rated voltage: 72.5 kV | 1 nos · 4-8 weeks | for verified buyers |
| Rated voltage145 kVMAR-ED4-06 | Rated voltage: 145 kV | 1 nos · 4-8 weeks | for verified buyers |
Specifications
| Rated voltage | 12 kV to 145 kV (see variants) |
|---|---|
| Component | Motor |
| Rated current | 3150 A |
| Short circuit rating | 40 kAmade to order: 25 kA / 31.5 kA |
| Mechanical life | 30000 operationsmade to order: 10000 operations |
| Coil voltage | 110 V DCmade to order: 220 V DC |
| Motor voltage | 230 V AC |
| Fits make | As per breaker nameplate |
| Packing | Foam lined box |
| Testing | Routine tested |
| Origin | OEMmade to order: Compatible |