Catalogue / Hydrogen sensors & safety systems
Thermal conductivity hydrogen analyser, Eco seriesSample
by Marwar New Energy (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Marwar New Energy (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
Marwar Eco thermal conductivity hydrogen analyser, offered in 4 detection range options from 0-1000 ppm to 0-100% vol. Key features: remote calibration support, local display with calibration and hot swap sensor head. Typically used for h2 refuelling stations, refineries and battery rooms. Designed and tested to IEC 60079-29-1, IEC 60079-0 and IEC 61508 (SIL 2). Lead time 6-8 weeks; delivers to All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Marwar
- Model
- MAR-E42 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 10 nos
- Lead time
- 6-8 weeks
- Warranty
- 12 months
- Standards
- IEC 60079-29-1, IEC 60079-0, IEC 61508 (SIL 2)
- Delivers to
- All India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Wooden crate, seaworthy
- Delivery terms
- FOR nearest railhead
- Returns
- No returns on made-to-order items
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Detection range0-1000 ppmMAR-E42-01 | Detection range: 0-1000 ppm | 10 nos · 6-8 weeks | for verified buyers |
| Detection range0-4% volMAR-E42-02 | Detection range: 0-4% vol | 10 nos · 6-8 weeks | for verified buyers |
| Detection range0-100% LELMAR-E42-03 | Detection range: 0-100% LEL | 10 nos · 6-8 weeks | for verified buyers |
| Detection range0-100% volMAR-E42-04 | Detection range: 0-100% vol | 10 nos · 6-8 weeks | for verified buyers |
Specifications
| Detection range | 0-1000 ppm to 0-100% vol (see variants) |
|---|---|
| Sensor type | Thermal conductivity |
| Output | Relay |
| Response time T90 | < 10 smade to order: < 30 s |
| Accuracy | +/- 5% of FS |
| Hazardous area | Ex d IIC T4 |
| Supply | 24 V DC |
| Ingress protection | IP65made to order: IP66 |
| Housing | SS 316made to order: Aluminium |
| Operating temperature | -40 to 70 deg C |
| Calibration interval | 6 months |
| Alarm set points | 20% LEL |
| Sensor life | 3 years |