The Max range of outdoor RMU for distribution substations by Marwar covers 6 configuration options (2-way (LBS+LBS) to 5-way (3LBS+2VCB)). Key features: optional SCADA-ready motor operators and FPI, cable test facility on front panel and compact footprint for kiosk or indoor installation. Suited to urban 11 kV ring networks, residential and commercial campuses and metro and airport distribution. Designed and tested to IEC 62271-200, IEC 62271-103 and IEC 62271-105. Lead time 4-6 weeks; delivers to East & North-East India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Marwar
Model
MAR-164 series
Listing type
Product
Unit
nos
Minimum order
10 nos
Lead time
4-6 weeks
Warranty
12 months from commissioning
Standards
IEC 62271-200, IEC 62271-103, IEC 62271-105
Delivers to
East & North-East India
GST rate
18 %
Country of origin
India
Packaging
Steel skid with shrink wrap
Delivery terms
Ex-works, freight extra at actuals
Returns
Replacement of items damaged in transit within 7 days
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Configuration2-way (LBS+LBS)MAR-164-01Configuration: 2-way (LBS+LBS)10 nos · 4-6 weeksfor verified buyers
Configuration3-way (LBS+LBS+TF)MAR-164-02Configuration: 3-way (LBS+LBS+TF)10 nos · 4-6 weeksfor verified buyers
Configuration3-way (LBS+LBS+VCB)MAR-164-03Configuration: 3-way (LBS+LBS+VCB)10 nos · 4-6 weeksfor verified buyers
Configuration4-way (2LBS+LBS+VCB)MAR-164-04Configuration: 4-way (2LBS+LBS+VCB)10 nos · 4-6 weeksfor verified buyers
Configuration4-way (3LBS+TF)MAR-164-05Configuration: 4-way (3LBS+TF)10 nos · 8-12 weeksfor verified buyers
Configuration5-way (3LBS+2VCB)MAR-164-06Configuration: 5-way (3LBS+2VCB)10 nos · 8-12 weeksfor verified buyers

Specifications

Configuration2-way (LBS+LBS) to 5-way (3LBS+2VCB) (see variants)
Rated voltage12 kV
Rated current - ring400 Amade to order: 630 A
Transformer feeder200 A fuse-switch
Short-circuit rating16 kA/3 s
Insulation mediumSF6 gas
Switch typeDisconnector + earthing
ExtensibilityNon-extensiblemade to order: Extensible one side / Extensible both sides
Protection relaySelf-powered O/C-E/F relaymade to order: Numerical relay
Fault passage indicatorIncludedmade to order: Optional
EnclosureMild steel RAL 7035made to order: Stainless steel gas tank
Degree of protectionIP54made to order: IP67 tank
Motor operatorOptional on ring switches