Catalogue / Surge protection devices

No photo yet

DC surge protection device for solar (Type 2), Max seriesSample

by Mauryaakash Lightning Protection (Sample) · verified by BARREL

Price for verified buyers

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Mauryaakash Lightning Protection (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Register your company to see prices.

DC surge protection device for solar (Type 2) from Mauryaakash, Max series: 4 rating options between Type 2, 20 kA, 600 VDC and Type 2, 40 kA, 275 VAC. Highlights: suitable for 1000/1500 VDC solar strings, thermal disconnector with visual indication and pluggable modules allow replacement without shutdown. Suited to solar inverters and combiner boxes, telecom and data centres and LT panels and distribution boards. Designed and tested to IEC 61643-11, IEC 61643-31 and IS/IEC 61643-11. Lead time 3-4 weeks; delivers to East & North-East India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Mauryaakash
Model
MAU-771 series
Listing type
Product
Unit
nos
Minimum order
1 nos
Lead time
3-4 weeks
Warranty
5 years
Standards
IEC 61643-11, IEC 61643-31, IS/IEC 61643-11
Delivers to
East & North-East India
GST rate
18 %
Country of origin
India
Packaging
Steel skid with shrink wrap
Delivery terms
Door delivery in metro cities
Returns
Replacement of items damaged in transit within 7 days
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
RatingType 2, 20 kA, 600 VDCMAU-771-01Rating: Type 2, 20 kA, 600 VDC1 nos · 3-4 weeksfor verified buyers
RatingType 2, 40 kA, 1000 VDCMAU-771-02Rating: Type 2, 40 kA, 1000 VDC1 nos · 3-4 weeksfor verified buyers
RatingType 2, 40 kA, 1500 VDCMAU-771-03Rating: Type 2, 40 kA, 1500 VDC1 nos · 3-4 weeksfor verified buyers
RatingType 2, 40 kA, 275 VACMAU-771-04Rating: Type 2, 40 kA, 275 VAC1 nos · 3-4 weeksfor verified buyers

Specifications

RatingType 2, 20 kA, 600 VDC to Type 2, 40 kA, 275 VAC (see variants)
SPD classType 1
Max continuous voltage (Uc)1500 VDCmade to order: 275 VAC / 440 VAC / 1000 VDC
Nominal discharge current (In)20 kA
Max discharge current (Imax)40 kA
Voltage protection level (Up)≤ 1.5 kVmade to order: ≤ 2.5 kV / ≤ 4 kV
TechnologyMetal oxide varistormade to order: Gas discharge tube
Poles2made to order: 1 / 3 / 4
IndicationVisual window
Plug-in modulesReplaceable cartridges
Back-up fuseRecommended 125 A gG
MountingDIN rail 35 mm