Catalogue / Surge protection devices
DC surge protection device for solar (Type 2), Max seriesSample
by Mauryaakash Lightning Protection (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Mauryaakash Lightning Protection (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
DC surge protection device for solar (Type 2) from Mauryaakash, Max series: 4 rating options between Type 2, 20 kA, 600 VDC and Type 2, 40 kA, 275 VAC. Highlights: suitable for 1000/1500 VDC solar strings, thermal disconnector with visual indication and pluggable modules allow replacement without shutdown. Suited to solar inverters and combiner boxes, telecom and data centres and LT panels and distribution boards. Designed and tested to IEC 61643-11, IEC 61643-31 and IS/IEC 61643-11. Lead time 3-4 weeks; delivers to East & North-East India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Mauryaakash
- Model
- MAU-771 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 1 nos
- Lead time
- 3-4 weeks
- Warranty
- 5 years
- Standards
- IEC 61643-11, IEC 61643-31, IS/IEC 61643-11
- Delivers to
- East & North-East India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Steel skid with shrink wrap
- Delivery terms
- Door delivery in metro cities
- Returns
- Replacement of items damaged in transit within 7 days
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| RatingType 2, 20 kA, 600 VDCMAU-771-01 | Rating: Type 2, 20 kA, 600 VDC | 1 nos · 3-4 weeks | for verified buyers |
| RatingType 2, 40 kA, 1000 VDCMAU-771-02 | Rating: Type 2, 40 kA, 1000 VDC | 1 nos · 3-4 weeks | for verified buyers |
| RatingType 2, 40 kA, 1500 VDCMAU-771-03 | Rating: Type 2, 40 kA, 1500 VDC | 1 nos · 3-4 weeks | for verified buyers |
| RatingType 2, 40 kA, 275 VACMAU-771-04 | Rating: Type 2, 40 kA, 275 VAC | 1 nos · 3-4 weeks | for verified buyers |
Specifications
| Rating | Type 2, 20 kA, 600 VDC to Type 2, 40 kA, 275 VAC (see variants) |
|---|---|
| SPD class | Type 1 |
| Max continuous voltage (Uc) | 1500 VDCmade to order: 275 VAC / 440 VAC / 1000 VDC |
| Nominal discharge current (In) | 20 kA |
| Max discharge current (Imax) | 40 kA |
| Voltage protection level (Up) | ≤ 1.5 kVmade to order: ≤ 2.5 kV / ≤ 4 kV |
| Technology | Metal oxide varistormade to order: Gas discharge tube |
| Poles | 2made to order: 1 / 3 / 4 |
| Indication | Visual window |
| Plug-in modules | Replaceable cartridges |
| Back-up fuse | Recommended 125 A gG |
| Mounting | DIN rail 35 mm |