Signal and data line surge protector from Maurya, Pro 9 series: 4 rating options between Type 2, 20 kA, 600 VDC and Type 2, 40 kA, 275 VAC. Highlights: low Up for sensitive electronics, thermal disconnector with visual indication and remote signalling contact. Suited to LT panels and distribution boards, control and SCADA rooms and telecom and data centres. Designed and tested to IEC 61643-11, IEC 61643-31 and IS/IEC 61643-11. Lead time 1-2 weeks; delivers to All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Maurya
Model
MAU-BD5 series
Listing type
Product
Unit
nos
Minimum order
5 nos
Lead time
1-2 weeks
Warranty
24 months
Standards
IEC 61643-11, IEC 61643-31, IS/IEC 61643-11
Delivers to
All India
GST rate
18 %
Country of origin
India
Packaging
As per item, transit-safe
Delivery terms
Ex-works, freight extra at actuals
Returns
No returns on made-to-order items
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
RatingType 2, 20 kA, 600 VDCMAU-BD5-01Rating: Type 2, 20 kA, 600 VDC5 nos · 1-2 weeksfor verified buyers
RatingType 2, 40 kA, 1000 VDCMAU-BD5-02Rating: Type 2, 40 kA, 1000 VDC5 nos · 1-2 weeksfor verified buyers
RatingType 2, 40 kA, 1500 VDCMAU-BD5-03Rating: Type 2, 40 kA, 1500 VDC5 nos · 3-4 weeksfor verified buyers
RatingType 2, 40 kA, 275 VACMAU-BD5-04Rating: Type 2, 40 kA, 275 VAC5 nos · 3-4 weeksfor verified buyers

Specifications

RatingType 2, 20 kA, 600 VDC to Type 2, 40 kA, 275 VAC (see variants)
SPD classType 2
Max continuous voltage (Uc)1000 VDC
Nominal discharge current (In)40 kAmade to order: 20 kA
Max discharge current (Imax)40 kA
Voltage protection level (Up)≤ 1.5 kVmade to order: ≤ 2.5 kV / ≤ 4 kV
TechnologyGas discharge tubemade to order: Metal oxide varistor
Poles4made to order: 1 / 2 / 3
IndicationVisual window
Plug-in modulesReplaceable cartridges
Back-up fuseRecommended 125 A gG
MountingDIN rail 35 mm

BARREL: Bharat Atom Renewable Resources Energy Limited