Catalogue / Transformer plinths, oil pits & soak pits
Fire wall between transformers, Edge seriesSample
by Mewararc Infrastructure (Sample) · verified by BARREL
Price on quote
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Mewararc Infrastructure (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Fire wall between transformers from Mewararc, Edge series: 5 transformer rating served options between 315 kVA and 31.5 MVA. Highlights: rail track for transformer trolley, pits with removable gratings and flame arrester stone bed. Suited to power substations, generation transformer bays and captive power plants. Delivered in line with IS 456, IS 10028 (Part 2) and CBIP Manual 317. Mobilisation 4-6 weeks; serves All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Mewararc
- Model
- MEW-A62 series
- Listing type
- Service
- Unit
- nos
- Minimum order
- 1 nos
- Lead time
- 4-6 weeks
- Warranty
- 12 months defect liability
- Standards
- IS 456, IS 10028 (Part 2), CBIP Manual 317
- Delivers to
- All India
- GST rate
- 18 %
- Country of origin
- India
- Delivery terms
- Site mobilisation as per work order
- Returns
- Re-work of defective scope at no cost
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Transformer rating served315 kVAMEW-A62-01 | Transformer rating served: 315 kVA | 1 nos · 4-6 weeks | on quote |
| Transformer rating served1 MVAMEW-A62-02 | Transformer rating served: 1 MVA | 1 nos · 4-6 weeks | on quote |
| Transformer rating served5 MVAMEW-A62-03 | Transformer rating served: 5 MVA | 1 nos · 4-6 weeks | on quote |
| Transformer rating served10 MVAMEW-A62-04 | Transformer rating served: 10 MVA | 1 nos · 4-6 weeks | on quote |
| Transformer rating served31.5 MVAMEW-A62-05 | Transformer rating served: 31.5 MVA | 1 nos · 4-6 weeks | on quote |
Specifications
| Transformer rating served | 315 kVA to 31.5 MVA (see variants) |
|---|---|
| Concrete grade | M30 |
| Oil pit capacity | 110% of oil volumemade to order: 150% of oil volume |
| Pit fill | Gravel 400 mm |
| Pit waterproofing | Integral waterproofingmade to order: Epoxy coating |
| Drain pipe | 150 NB |
| Fire wall height | 4 mmade to order: None / 3 m |
| Fire wall thickness | 300 mm RCC |
| Rail track | ISMB 150 rails |
| Reinforcement | Fe 500D |
| Earth pit | 2 nos |