Mewar Plus three-phase encapsulated GIS, offered in 5 system voltage options from 36 kV to 420 kV. Highlights: UHF partial discharge sensors, suitable for indoor and outdoor and gas compartment with density monitors. Used by metro rail traction, industrial plants and offshore and hilly regions. Designed and tested to IEC 62271-203, IEC 62271-1 and IEC 62271-100. Lead time 40-52 weeks; delivers to West India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Mewar
- Model
- MEW-AC1 series
- Listing type
- Product
- Unit
- bay
- Minimum order
- 2 bay
- Lead time
- 40-52 weeks
- Warranty
- 36 months
- Standards
- IEC 62271-203, IEC 62271-1, IEC 62271-100
- Delivers to
- West India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Steel skid with shrink wrap
- Delivery terms
- FOR site, freight included
- Returns
- Replacement of items damaged in transit within 7 days
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| System voltage36 kVMEW-AC1-01 | System voltage: 36 kV | 2 bay · 40-52 weeks | for verified buyers |
| System voltage72.5 kVMEW-AC1-02 | System voltage: 72.5 kV | 2 bay · 40-52 weeks | for verified buyers |
| System voltage145 kVMEW-AC1-03 | System voltage: 145 kV | 2 bay · 40-52 weeks | for verified buyers |
| System voltage245 kVMEW-AC1-04 | System voltage: 245 kV | 2 bay · 40-52 weeks | for verified buyers |
| System voltage420 kVMEW-AC1-05 | System voltage: 420 kV | 2 bay · 40-52 weeks | for verified buyers |
Specifications
| System voltage | 36 kV to 420 kV (see variants) |
|---|---|
| Rated current | 4000 A |
| Short-circuit current | 31.5 kAmade to order: 40 kA / 50 kA |
| Configuration | Ring busmade to order: Single bus / Double bus |
| Enclosure | Steelmade to order: Aluminium alloy |
| Gas | Clean airmade to order: SF6 / SF6/N2 mix |
| Bay width | 2500 mm |
| Operating mechanism | Motor |
| Partial discharge monitoring | UHF sensors |
| Control | Local control cubicle with BCU |
| Gas leakage | < 0.1% per year |
| Earth switches | Maintenance + fast acting |
| Interlocks | Mechanical and electrical |