Catalogue / Transformer overhaul & oil filtration

No photo yet

Transformer oil filtration and dehydration, Ultra 3 seriesSample

by Mysore Consultants (Sample) · verified by BARREL

Price for verified buyers

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Mysore Consultants (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Register your company to see prices.

The Ultra 3 service of transformer oil filtration and dehydration by Mysore covers 3 transformer rating options (20 MVA to 100 MVA). Key features: oil sampling and DGA before work, nitrogen or dry air purge on opening and core insulation resistance checks. Suited to state utility asset life extension, captive power plants and solar and wind pooling substations. Delivered in line with IS 335 (Mineral Insulating Oil), IS 1866 (Oil Maintenance) and IEC 60422. Mobilisation Planned shutdown required; serves All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Mysore
Model
MYS-794 series
Listing type
Service
Unit
nos
Minimum order
1 nos
Lead time
Planned shutdown required
Warranty
Workmanship 12 months
Standards
IS 335 (Mineral Insulating Oil), IS 1866 (Oil Maintenance), IEC 60422
Delivers to
All India
GST rate
18 %
Country of origin
India
Delivery terms
Site mobilisation as per work order
Returns
Re-work of defective scope at no cost
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Transformer rating20 MVAMYS-794-01Transformer rating: 20 MVA1 nos · Planned shutdown requiredfor verified buyers
Transformer rating50 MVAMYS-794-02Transformer rating: 50 MVA1 nos · Planned shutdown requiredfor verified buyers
Transformer rating100 MVAMYS-794-03Transformer rating: 100 MVA1 nos · Planned shutdown requiredfor verified buyers

Specifications

Transformer rating20 MVA to 100 MVA (see variants)
ServiceFull overhaul with rewindingmade to order: Oil filtration and dehydration / Oil reclamation / Internal inspection and overhaul
Filtration machineVacuum dehydration 6000 L/hrmade to order: Mobile 12000 L/hr
Oil BDV targetAbove 70 kVmade to order: Above 60 kV
Moisture targetBelow 10 ppm
TestingDGA, furan, BDV, tan deltamade to order: Full routine tests after overhaul
SparesBushings and OLTC parts at costmade to order: Gaskets and silica gel
Downtime2-3 days
Site workWorkshop repairmade to order: Hot oil circulation at site
Crew4 technicians with supervisormade to order: Specialised overhaul team
CertificateOverhaul report with test datamade to order: Oil test report from NABL lab

BARREL: Bharat Atom Renewable Resources Energy Limited