Catalogue / Substation & line O&M

No photo yet

Battery bank and DC system maintenance, Volt 4 seriesSample

by Mysore Consultants (Sample) · verified by BARREL

Price on quote

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Mysore Consultants (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

The Volt 4 service of battery bank and DC system maintenance by Mysore covers 6 voltage level options (11 kV to 400 kV). Key features: insulator and joint inspection, permit-to-work and lockout-tagout and licensed supervisory staff. Suited to railway and metro sub-stations, industrial captive substations and renewable pooling substations. Delivered in line with CEA (Measures relating to Safety) Regulations, CEA (Grid Standards) Regulations and IS 10028 (Transformer Installation). Mobilisation Mobilisation in 2-3 weeks; serves All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Mysore
Model
MYS-CB6 series
Listing type
Service
Unit
month
Minimum order
1 month
Lead time
Mobilisation in 2-3 weeks
Warranty
As per contract
Standards
CEA (Measures relating to Safety) Regulations, CEA (Grid Standards) Regulations, IS 10028 (Transformer Installation)
Delivers to
All India
GST rate
18 %
Country of origin
India
Delivery terms
Site mobilisation as per work order
Returns
Re-work of defective scope at no cost
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Voltage level11 kVMYS-CB6-01Voltage level: 11 kV1 month · Mobilisation in 2-3 weekson quote
Voltage level33 kVMYS-CB6-02Voltage level: 33 kV1 month · Mobilisation in 2-3 weekson quote
Voltage level66 kVMYS-CB6-03Voltage level: 66 kV1 month · Mobilisation in 2-3 weekson quote
Voltage level132 kVMYS-CB6-04Voltage level: 132 kV1 month · Mobilisation in 2-3 weekson quote
Voltage level220 kVMYS-CB6-05Voltage level: 220 kV1 month · Baseline condition audit firston quote
Voltage level400 kVMYS-CB6-06Voltage level: 400 kV1 month · Baseline condition audit firston quote

Specifications

Voltage level11 kV to 400 kV (see variants)
ScopeOperation and maintenancemade to order: Maintenance only / Operation, maintenance and statutory compliance
Shift pattern3 shifts, 24x7made to order: General shift plus on-call
ManpowerEngineer plus 6 operatorsmade to order: Two engineers plus 12 staff
Line patrollingMonthly foot patrol
TestingAnnual relay and CT/PT test
Statutory recordsCEIG renewal support
SparesConsumables includedmade to order: Critical spares by owner
Response time2 hours for tripmade to order: 4 hours
ReportingMonthly fault and maintenance reportmade to order: Real-time dashboards
Term3 years