Catalogue / Substation construction
Switchyard erection and bus bar works, Pro seriesSample
by Mysore Consultants (Sample) · verified by BARREL
Price on quote
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Mysore Consultants (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Mysore Pro switchyard erection and bus bar works, offered in 4 voltage class options from 66 kV to 400 kV. Key features: battery and DC system installation, pre-commissioning tests before CEIG visit and earth grid designed for fault level and soil resistivity. Typically used for state utility augmentation, industrial captive substations and renewable pooling stations. Delivered in line with CEA (Technical Standards for Construction of Electrical Plants) Regulations, IEC 61936-1 and IS 3043 (Earthing). Mobilisation Execution 6-15 months; serves All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Mysore
- Model
- MYS-093 series
- Listing type
- Service
- Unit
- bay
- Minimum order
- 1 bay
- Lead time
- Execution 6-15 months
- Warranty
- Equipment as per OEM
- Standards
- CEA (Technical Standards for Construction of Electrical Plants) Regulations, IEC 61936-1, IS 3043 (Earthing)
- Delivers to
- All India
- GST rate
- 18 %
- Country of origin
- India
- Delivery terms
- Site mobilisation as per work order
- Returns
- Re-work of defective scope at no cost
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Voltage class66 kVMYS-093-01 | Voltage class: 66 kV | 1 bay · Execution 6-15 months | on quote |
| Voltage class132 kVMYS-093-02 | Voltage class: 132 kV | 1 bay · Execution 6-15 months | on quote |
| Voltage class220 kVMYS-093-03 | Voltage class: 220 kV | 1 bay · Execution 6-15 months | on quote |
| Voltage class400 kVMYS-093-04 | Voltage class: 400 kV | 1 bay · Execution 6-15 months | on quote |
Specifications
| Voltage class | 66 kV to 400 kV (see variants) |
|---|---|
| Type | Outdoor AIS |
| Scope | Erection and testing |
| Transformers | Up to 50 MVAmade to order: Up to 160 MVA / Up to 315 MVA |
| Earthing | GI flat grid with ground rods |
| Bay count | 2-4 baysmade to order: 6-10 bays |
| Protection scheme | Main-1 and Main-2 relays |
| SCADA and communication | IEC 60870-5-104 |
| Statutory | CEIG inspection supportmade to order: STU charging approval |
| Duration | 6-9 months |
| Payment terms | Percentage on supply, erectionmade to order: Milestone: 10/70/10/10 |