Catalogue / Ring main units (RMU)
SF6 insulated compact RMU, Pro seriesSample
by Mysoreohm Panels (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Mysoreohm Panels (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
SF6 insulated compact RMU from Mysoreohm, Pro series: 3 configuration options between 3-way (LBS+LBS+VCB) and 4-way (3LBS+TF). Highlights: optional SCADA-ready motor operators and FPI, sealed-for-life gas tank unaffected by humidity or dust and cable test facility on front panel. Typically used for discom compact substations, urban 11 kV ring networks and residential and commercial campuses. Designed and tested to IEC 62271-200, IEC 62271-103 and IEC 62271-105. Lead time 8-12 weeks; delivers to All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Mysoreohm
- Model
- MYS-996 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 1 nos
- Lead time
- 8-12 weeks
- Warranty
- 24 months from supply
- Standards
- IEC 62271-200, IEC 62271-103, IEC 62271-105
- Delivers to
- All India and export (SAARC, Middle East, Africa)
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Steel skid with shrink wrap
- Delivery terms
- FOR nearest railhead
- Returns
- Replacement of items damaged in transit within 7 days
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Configuration3-way (LBS+LBS+VCB)MYS-996-01 | Configuration: 3-way (LBS+LBS+VCB) | 1 nos · 8-12 weeks | for verified buyers |
| Configuration4-way (2LBS+LBS+VCB)MYS-996-02 | Configuration: 4-way (2LBS+LBS+VCB) | 1 nos · 8-12 weeks | for verified buyers |
| Configuration4-way (3LBS+TF)MYS-996-03 | Configuration: 4-way (3LBS+TF) | 1 nos · 8-12 weeks | for verified buyers |
Specifications
| Configuration | 3-way (LBS+LBS+VCB) to 4-way (3LBS+TF) (see variants) |
|---|---|
| Rated voltage | 12 kV |
| Rated current - ring | 400 Amade to order: 630 A |
| Transformer feeder | 630 A VCB |
| Short-circuit rating | 20 kA/3 smade to order: 16 kA/3 s / 25 kA/3 s |
| Insulation medium | SF6 gas |
| Switch type | Three-position load-breakmade to order: Disconnector + earthing |
| Extensibility | Extensible both sides |
| Protection relay | Numerical relaymade to order: Self-powered O/C-E/F relay |
| Fault passage indicator | Includedmade to order: Optional |
| Enclosure | Mild steel RAL 7035made to order: Stainless steel gas tank |
| Degree of protection | IP67 tankmade to order: IP54 |
| Motor operator | Not fitted |