Catalogue / Synchronising panels
Load-sharing paralleling panel, Duo 4 seriesSample
by Nalandakelvin Rotating Machines (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Nalandakelvin Rotating Machines (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
Nalandakelvin Duo 4 load-sharing paralleling panel, offered in 4 gensets in parallel options from 3 gensets to 8 gensets. Highlights: auto sync on generator bus, mains paralleling with export protection and remote status via SCADA. Suited to hospitals and industries, multi-genset data centres and power plants with parallel DG. Designed and tested to IEC 61439-2, IS 8623 and IEC 60947-2. Lead time 4-6 weeks; delivers to All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Nalandakelvin
- Model
- NAL-8F4 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 1 nos
- Lead time
- 4-6 weeks
- Warranty
- 12 months
- Standards
- IEC 61439-2, IS 8623, IEC 60947-2
- Delivers to
- All India and export (SAARC, Middle East, Africa)
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Corrugated box on pallet
- Delivery terms
- FOR site, freight included
- Returns
- Returns within 15 days if unused, in original packing
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Gensets in parallel3 gensetsNAL-8F4-01 | Gensets in parallel: 3 gensets | 1 nos · 4-6 weeks | for verified buyers |
| Gensets in parallel4 gensetsNAL-8F4-02 | Gensets in parallel: 4 gensets | 1 nos · 4-6 weeks | for verified buyers |
| Gensets in parallel6 gensetsNAL-8F4-03 | Gensets in parallel: 6 gensets | 1 nos · 8-12 weeks | for verified buyers |
| Gensets in parallel8 gensetsNAL-8F4-04 | Gensets in parallel: 8 gensets | 1 nos · 8-12 weeks | for verified buyers |
Specifications
| Gensets in parallel | 3 gensets to 8 gensets (see variants) |
|---|---|
| Bus rating | 4000 A |
| Voltage | 11 kV |
| Fault level | 65 kAmade to order: 50 kA / 85 kA |
| Controller | Genset controller per setmade to order: PLC master |
| Breaker | VCBmade to order: ACB |
| Load sharing | Droopmade to order: Isochronous |
| Protections | Reverse power, overcurrent, earth fault |
| Communication | Ethernetmade to order: Modbus |
| Form of separation | Form 4b |
| Enclosure | IP42made to order: IP54 |
| Mains parallel | No |