Catalogue / Synchronising panels
Bus-tie and mains-synchronising panel, Titan seriesSample
by Nalandakelvin Rotating Machines (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Nalandakelvin Rotating Machines (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
Bus-tie and mains-synchronising panel from Nalandakelvin, Titan series: 5 gensets in parallel options between 2 gensets and 8 gensets. Highlights: auto start-stop on load demand, kW and kVAR load sharing and mains paralleling with export protection. Used by power plants with parallel DG, hospitals and industries and large commercial complexes. Designed and tested to IEC 61439-2, IS 8623 and IEC 60947-2. Lead time 4-6 weeks; delivers to All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Nalandakelvin
- Model
- NAL-B68 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 5 nos
- Lead time
- 4-6 weeks
- Warranty
- 12 months
- Standards
- IEC 61439-2, IS 8623, IEC 60947-2
- Delivers to
- All India and export (SAARC, Middle East, Africa)
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Steel skid with shrink wrap
- Delivery terms
- FOR site, freight included
- Returns
- Replacement of items damaged in transit within 7 days
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Gensets in parallel2 gensetsNAL-B68-01 | Gensets in parallel: 2 gensets | 5 nos · 4-6 weeks | for verified buyers |
| Gensets in parallel3 gensetsNAL-B68-02 | Gensets in parallel: 3 gensets | 5 nos · 4-6 weeks | for verified buyers |
| Gensets in parallel4 gensetsNAL-B68-03 | Gensets in parallel: 4 gensets | 5 nos · 4-6 weeks | for verified buyers |
| Gensets in parallel6 gensetsNAL-B68-04 | Gensets in parallel: 6 gensets | 5 nos · 8-12 weeks | for verified buyers |
| Gensets in parallel8 gensetsNAL-B68-05 | Gensets in parallel: 8 gensets | 5 nos · 8-12 weeks | for verified buyers |
Specifications
| Gensets in parallel | 2 gensets to 8 gensets (see variants) |
|---|---|
| Bus rating | 1600 A |
| Voltage | 11 kV |
| Fault level | 85 kAmade to order: 50 kA / 65 kA |
| Controller | PLC master |
| Breaker | VCB |
| Load sharing | Isochronousmade to order: Droop |
| Protections | Reverse power, overcurrent, earth fault |
| Communication | Modbusmade to order: Ethernet |
| Form of separation | Form 3b |
| Enclosure | IP42made to order: IP54 |
| Mains parallel | Yesmade to order: No |