Catalogue / Aspirating smoke detection
Aspirating detector with pipe network, Flex seriesSample
by Nandimark Fire Systems (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Nandimark Fire Systems (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
The Flex range of aspirating detector with pipe network by Nandimark covers 5 coverage options (Up to 250 m² / 1 pipe to Up to 4000 m²). Highlights: integration with gas suppression panel, fault-monitored pipe network and airflow and four alarm levels for graded response. Typically used for battery energy storage containers, cable tunnels and galleries and high-bay warehouses. Designed and tested to EN 54-20, NFPA 76 and NFPA 72. Lead time 3-4 weeks; delivers to All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Nandimark
- Model
- NAN-7D5 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 5 nos
- Lead time
- 3-4 weeks
- Warranty
- 24 months from supply
- Standards
- EN 54-20, NFPA 76, NFPA 72
- Delivers to
- All India
- GST rate
- 18 %
- Country of origin
- India (imported sub-assemblies)
- Packaging
- Drum / reel with end caps
- Delivery terms
- Ex-works, freight extra at actuals
- Returns
- Replacement of items damaged in transit within 7 days
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| CoverageUp to 250 m² / 1 pipeNAN-7D5-01 | Coverage: Up to 250 m² / 1 pipe | 5 nos · 3-4 weeks | for verified buyers |
| CoverageUp to 500 m² / 2 pipesNAN-7D5-02 | Coverage: Up to 500 m² / 2 pipes | 5 nos · 3-4 weeks | for verified buyers |
| CoverageUp to 1000 m² / 4 pipesNAN-7D5-03 | Coverage: Up to 1000 m² / 4 pipes | 5 nos · 3-4 weeks | for verified buyers |
| CoverageUp to 2000 m²NAN-7D5-04 | Coverage: Up to 2000 m² | 5 nos · 6-8 weeks | for verified buyers |
| CoverageUp to 4000 m²NAN-7D5-05 | Coverage: Up to 4000 m² | 5 nos · 6-8 weeks | for verified buyers |
Specifications
| Coverage | Up to 250 m² / 1 pipe to Up to 4000 m² (see variants) |
|---|---|
| Sensitivity | Class A (very high)made to order: Class B / Class C |
| Detection | Laser light scattering |
| Alarm levels | Alert, Action, Fire 1, Fire 2 |
| Pipe network | Up to 400 m |
| Sampling holes | Up to 40 |
| Airflow monitoring | Yes, with fault alarm |
| Relays | 5 |
| Communication | Modbusmade to order: RS-485 / Ethernet |
| Power supply | 24 VDC |
| Dust filter | Replaceable |
| Operating temperature | -10 to 39 °C |
| Approval | EN 54-20made to order: UL 268 |