In-row cooling unit, Volt seriesSample
by Narmadakavach UPS Systems (Sample) · verified by BARREL
Price for verified buyers
Ordered and invoiced through BARREL — one contract, one GST invoice.
Customise and request quoteMade to order: change the marked specification rows to what you need; Narmadakavach UPS Systems (Sample) quotes for it.
Or send an open RFQ to every matching merchant.
Register your company to see prices.
Narmadakavach Volt in-row cooling unit, offered in 4 cooling capacity options from 15 kW to 50 kW. Key features: hot or cold aisle containment compatible, designed for continuous 24x7 operation and staggered restart after power failure. Suited to laboratories, data centres and network operation centres. Designed and tested to ASHRAE TC 9.9, ISO 5151 and IS 1391 (Part 1). Lead time 8-10 weeks; delivers to All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Narmadakavach
- Model
- NAR-2A1 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 10 nos
- Lead time
- 8-10 weeks
- Warranty
- 12 months from commissioning
- Standards
- ASHRAE TC 9.9, ISO 5151, IS 1391 (Part 1)
- Delivers to
- All India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- Corrugated box on pallet
- Delivery terms
- Door delivery in metro cities
- Returns
- Replacement of items damaged in transit within 7 days
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Cooling capacity15 kWNAR-2A1-01 | Cooling capacity: 15 kW | 10 nos · 8-10 weeks | for verified buyers |
| Cooling capacity25 kWNAR-2A1-02 | Cooling capacity: 25 kW | 10 nos · 8-10 weeks | for verified buyers |
| Cooling capacity35 kWNAR-2A1-03 | Cooling capacity: 35 kW | 10 nos · 8-10 weeks | for verified buyers |
| Cooling capacity50 kWNAR-2A1-04 | Cooling capacity: 50 kW | 10 nos · 8-10 weeks | for verified buyers |
Specifications
| Cooling capacity | 15 kW to 50 kW (see variants) |
|---|---|
| Type | DX air-cooled |
| Airflow | Downflow |
| Compressor | Scrollmade to order: Inverter scroll / Not applicable |
| Fan | EC plug fanmade to order: Backward-curved EC |
| Sensible heat ratio | Above 0.9 |
| Humidification | Infraredmade to order: Electrode steam / None |
| Dehumidification | Hot-gas reheat |
| Control | BMS via Modbus |
| Supply | 415 V 3-phase 50 Hz |
| Refrigerant | R407Cmade to order: R410A / R134a |
| Condenser | Remote air-cooled |
| Filtration | G4made to order: F5 |