Dry-type auxiliary service transformer, Prime seriesSample

by Narmadapushpak Power Transformers (Sample) · verified by BARREL

Price for verified buyers

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Narmadapushpak Power Transformers (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Register your company to see prices.

Dry-type auxiliary service transformer from Narmadapushpak, Prime series: 5 rating options between 100 kVA and 1600 kVA. Key features: limits fault current to relay-set value, complete with neutral CT and links and suitable for outdoor substation. Suited to wind farm collector systems, substation auxiliary supply and power plant station service. Designed and tested to IS 1180, IS 2026 and IEC 60076. Lead time 8-10 weeks; delivers to All India and export (SAARC, Middle East, Africa). Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Narmadapushpak
Model
NAR-A84 series
Listing type
Product
Unit
nos
Minimum order
1 nos
Lead time
8-10 weeks
Warranty
18 months
Standards
IS 1180, IS 2026, IEC 60076
Delivers to
All India and export (SAARC, Middle East, Africa)
GST rate
18 %
Country of origin
India
Packaging
Corrugated box on pallet
Delivery terms
Ex-works, freight extra at actuals
Returns
Replacement of items damaged in transit within 7 days
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
Rating100 kVANAR-A84-01Rating: 100 kVA1 nos · 8-10 weeksfor verified buyers
Rating315 kVANAR-A84-02Rating: 315 kVA1 nos · 8-10 weeksfor verified buyers
Rating630 kVANAR-A84-03Rating: 630 kVA1 nos · 8-10 weeksfor verified buyers
Rating1000 kVANAR-A84-04Rating: 1000 kVA1 nos · 8-10 weeksfor verified buyers
Rating1600 kVANAR-A84-05Rating: 1600 kVA1 nos · 8-10 weeksfor verified buyers

Specifications

Rating100 kVA to 1600 kVA (see variants)
TypeAuxiliary (Dyn11)made to order: Earthing (zig-zag) / Station service
Primary voltage33 kV
Secondary voltage0.433 kV
Short-time rating10 smade to order: 30 s
Neutral current200 Amade to order: 400 A / 800 A
CoolingDry ANmade to order: ONAN
Vector groupDyn11
ImpedanceLow zero-sequence
Tap changerOff-circuit +/- 5%
TerminationCable box
MountingSkidmade to order: Plinth
Neutral protectionCT on neutral

BARREL: Bharat Atom Renewable Resources Energy Limited