Aspirating detector with pipe network, Volt 2 seriesSample

by Nilgiri Fire Systems (Sample) · verified by BARREL

Price for verified buyers

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Nilgiri Fire Systems (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Register your company to see prices.

Aspirating detector with pipe network from Nilgiri, Volt 2 series: 5 coverage options between Up to 250 m² / 1 pipe and Up to 4000 m². Highlights: dust-immune with laser detection, remote configuration and event log and four alarm levels for graded response. Used by battery energy storage containers, data centres and control rooms and cable tunnels and galleries. Designed and tested to EN 54-20, NFPA 76 and NFPA 72. Lead time 6-8 weeks; delivers to All India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Nilgiri
Model
NIL-7D2 series
Listing type
Product
Unit
nos
Minimum order
1 nos
Lead time
6-8 weeks
Warranty
36 months from supply
Standards
EN 54-20, NFPA 76, NFPA 72
Delivers to
All India
GST rate
18 %
Country of origin
India
Packaging
Wooden crate, seaworthy
Delivery terms
Ex-works, freight extra at actuals
Returns
No returns on made-to-order items
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
CoverageUp to 250 m² / 1 pipeNIL-7D2-01Coverage: Up to 250 m² / 1 pipe1 nos · 6-8 weeksfor verified buyers
CoverageUp to 500 m² / 2 pipesNIL-7D2-02Coverage: Up to 500 m² / 2 pipes1 nos · 6-8 weeksfor verified buyers
CoverageUp to 1000 m² / 4 pipesNIL-7D2-03Coverage: Up to 1000 m² / 4 pipes1 nos · 6-8 weeksfor verified buyers
CoverageUp to 2000 m²NIL-7D2-04Coverage: Up to 2000 m²1 nos · 6-8 weeksfor verified buyers
CoverageUp to 4000 m²NIL-7D2-05Coverage: Up to 4000 m²1 nos · 6-8 weeksfor verified buyers

Specifications

CoverageUp to 250 m² / 1 pipe to Up to 4000 m² (see variants)
SensitivityClass B
DetectionLaser light scattering
Alarm levelsAlert, Action, Fire 1, Fire 2
Pipe networkUp to 100 mmade to order: Up to 400 m
Sampling holesUp to 40
Airflow monitoringYes, with fault alarm
Relays5
CommunicationEthernetmade to order: RS-485 / Modbus
Power supply24 VDC
Dust filterReplaceable
Operating temperature-10 to 39 °C
ApprovalUL 268