Genset to mains ATS panel with controller from Nilgirisudarshan, Ultra 4 series: 3 rating options between 250 A and 630 A. Key features: genset auto-start and cool-down logic, manual override for maintenance and event log and status LEDs on door. Suited to commercial buildings with DG sets, telecom and industrial facilities and hospitals and data centres. Designed and tested to IEC 60947-6-1, IS/IEC 60947-3 and IS 8623 (Part 1). Lead time 4-6 weeks; delivers to West India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.
- Brand
- Nilgirisudarshan
- Model
- NIL-253 series
- Listing type
- Product
- Unit
- nos
- Minimum order
- 2 nos
- Lead time
- 4-6 weeks
- Warranty
- 12 months from commissioning
- Standards
- IEC 60947-6-1, IS/IEC 60947-3, IS 8623 (Part 1)
- Delivers to
- West India
- GST rate
- 18 %
- Country of origin
- India
- Packaging
- As per item, transit-safe
- Delivery terms
- Door delivery in metro cities
- Returns
- Replacement of items damaged in transit within 7 days
- Other terms
- Sample data for testing; not a real offer.
Variants
| Variant | Specifications | Min. order · lead time | Price, ex GST |
|---|---|---|---|
| Rating250 ANIL-253-01 | Rating: 250 A | 2 nos · 4-6 weeks | for verified buyers |
| Rating400 ANIL-253-02 | Rating: 400 A | 2 nos · 4-6 weeks | for verified buyers |
| Rating630 ANIL-253-03 | Rating: 630 A | 2 nos · 4-6 weeks | for verified buyers |
Specifications
| Rating | 250 A to 630 A (see variants) |
|---|---|
| Type | ATS panelmade to order: Manual changeover / Motorised changeover |
| Poles | 3Pmade to order: 4P |
| Rated voltage | 415 V AC |
| Transfer device | Interlocked MCCB |
| Transition | Delayedmade to order: Open / Closed |
| Controller | Relay logicmade to order: Microprocessor ATS controller |
| Transfer time | Under 10 smade to order: Under 3 s |
| Mains failure delay | Adjustable 0-60 s |
| Short-circuit withstand | 10 kAmade to order: 25 kA / 36 kA / 50 kA |
| Enclosure | IP42 sheet steelmade to order: IP54 sheet steel |
| Auxiliary supply | 24 V DC |
| Genset start signal | Potential-free contactmade to order: CAN / Modbus |