Catalogue / Surge protection devices

No photo yet

DC surge protection device for solar (Type 2), Duo 8 seriesSample

by Pataliputraohm Earthing Solutions (Sample) · verified by BARREL

Price for verified buyers

Ordered and invoiced through BARREL — one contract, one GST invoice.

Customise and request quote

Made to order: change the marked specification rows to what you need; Pataliputraohm Earthing Solutions (Sample) quotes for it.

Or send an open RFQ to every matching merchant.

Register your company to see prices.

The Duo 8 range of DC surge protection device for solar (Type 2) by Pataliputraohm covers 3 rating options (Type 2, 20 kA, 600 VDC to Type 2, 40 kA, 1500 VDC). Key features: pluggable modules allow replacement without shutdown, tested to IEC 61643 series and remote signalling contact. Suited to LT panels and distribution boards, control and SCADA rooms and solar inverters and combiner boxes. Designed and tested to IEC 61643-11, IEC 61643-31 and IS/IEC 61643-11. Lead time 3-4 weeks; delivers to East & North-East India. Sample listing: illustrative data for testing BARREL Shop, not a real offer.

Brand
Pataliputraohm
Model
PAT-777 series
Listing type
Product
Unit
nos
Minimum order
1 nos
Lead time
3-4 weeks
Warranty
24 months
Standards
IEC 61643-11, IEC 61643-31, IS/IEC 61643-11
Delivers to
East & North-East India
GST rate
18 %
Country of origin
India
Packaging
Steel skid with shrink wrap
Delivery terms
Ex-works, freight extra at actuals
Returns
Replacement of items damaged in transit within 7 days
Other terms
Sample data for testing; not a real offer.

Variants

VariantSpecificationsMin. order · lead timePrice, ex GST
RatingType 2, 20 kA, 600 VDCPAT-777-01Rating: Type 2, 20 kA, 600 VDC1 nos · 3-4 weeksfor verified buyers
RatingType 2, 40 kA, 1000 VDCPAT-777-02Rating: Type 2, 40 kA, 1000 VDC1 nos · 3-4 weeksfor verified buyers
RatingType 2, 40 kA, 1500 VDCPAT-777-03Rating: Type 2, 40 kA, 1500 VDC1 nos · 3-4 weeksfor verified buyers

Specifications

RatingType 2, 20 kA, 600 VDC to Type 2, 40 kA, 1500 VDC (see variants)
SPD classType 2made to order: Type 1 / Type 1+2
Max continuous voltage (Uc)275 VACmade to order: 440 VAC / 1000 VDC / 1500 VDC
Nominal discharge current (In)40 kA
Max discharge current (Imax)80 kA
Voltage protection level (Up)≤ 1.5 kV
TechnologyGas discharge tube
Poles3
IndicationRemote contactmade to order: Visual window
Plug-in modulesReplaceable cartridges
Back-up fuseRecommended 125 A gG
MountingDIN rail 35 mm

BARREL: Bharat Atom Renewable Resources Energy Limited